0000000000326314
AUTHOR
J.g. March
Determination of selenium, zinc and cadmium in antidandruff shampoos by atomic spectrometry after microwave assisted sample digestion
Microwave assisted pre-treatments for atomic spectrometric determination (inductive coupled plasma-optical emission spectrometry, ICP-OES or flame atomic absorption spectrometry, FAAS) of metallic elements, usually present in antidandruff shampoos, are proposed. They are based on the digestion of the sample with HNO(3) into a closed reactor, which is irradiated at 800 W for a few minutes. Selenium was determined by ICP-OES. The limit of detection was 0.11 mg l(-1); the relative standard deviation (R.S.D.) for the selenium content in the samples was in the 0.6-3.6% range. The results obtained were in agreement with the label contents and the recovery of the proposed method was in the 100-106…
Sequential injection spectrophotometric determination of oxybenzone in lipsticks
A sequential injection (SI) procedure for the spectrophotometric determination of oxybenzone in lipsticks is reported. The colorimetric reaction between nickel and oxybenzone was used. SI parameters such as sample solution volume, reagent solution volume, propulsion flow rate and reaction coil length were studied. The limit of detection was 3 microg ml(-1). The sensitivity was 0.0108+/-0.0002 ml microg(-1). The relative standard deviations of the results were between 6 and 12%. The real concentrations of samples and the values obtained by HPLC were comparable. Microwave sample pre-treatment allowed the extraction of oxybenzone with ethanol, thus avoiding the use of toxic organic solvents. E…
General Review of Published Analytical Methods for Cosmetics
A simple novel configuration for in-vial microporous membrane liquid–liquid extraction
Abstract A novel arrangement for microporous membrane liquid–liquid extraction from the aqueous donor phase to the organic acceptor phase within a micro-vial, which is compatible with the chromatograph autosampler is presented. The device consisted of a stoppered glass micro-vial containing the organic solvent where the septum of the screw stopper was replaced by a sized piece of membrane which is hermetically assembled to the volumetric flask containing the aqueous donor solution. The placement of the membrane in alternative contact with the solutions was achieved by orbital agitation. As a preliminary study, 2-ethylhexyl 4-(dimethylamino)benzoate has been determined (limit of quantificati…
Analytical methodologies for atomic spectrometric determination of metallic oxides in UV sunscreen creams.
In this study, methodologies for determining titanium oxide, zinc oxide and iron oxide are proposed and assayed in commercial sunscreen products. The proposed methodology for TiO2, determination in sunscreens is based on a microwave-assisted treatment for digesting the organic components in a closed teflon reactor in presence of HNO3 and HCl. Titanium is determined by inductive coupled plasma emission spectrometry (ICP-AES). The proposed methodologies for measuring ZnO and Fe2O3 are based on a sample emulsification in water with a non ionic tensioactive and IBMK, followed by Zn and Fe determination by flame atomic absorption spectrometry (FAAS). The methodologies allow a precise and accurat…
Analytical Methods for Actives used in General and Specific Skin-Care, Personal Hygiene and other Toiletry Products (Excluding those Mentioned in Previous Chapters)
Indirect spectrophotometric determination of p-aminobenzoic acid in sunscreen formulations by sequential injection analysis
Abstract A simple indirect sequential injection spectrophotometric method for the determination of the UV-filter p -aminobenzoic acid (PABA) in sunscreen formulations is proposed. The determination is based on the reaction of PABA with hypochlorite in acidic medium and the subsequent measurement of the residual chlorine by using the well-known reaction with o -tolidine. The experimental variables involved in the sequential injection analysis (SIA) system (sandwich arrangement, volumes of sample and reagents, propulsion flow rate, reaction coil length) and adequate concentrations of reagents were studied. The SIA method has a linear range up to 20 μg ml −1 (3 s y / x / b detection limit) of …