0000000000334450

AUTHOR

Pasquarella C

risultati dello studio pilota del progetto spin uti: un modello per la valutazione ed il monitoraggio dei programmi in sanità pubblica

research product

Definition of criteria and indicators for the prevention of Healthcare-Associated Infections (HAIs) in hospitals for the purposes of Italian institutional accreditation and performance monitoring

Background. Healthcare-associated infections (HAIs) are an important issue in terms of quality of care. HAIs impact patient safety by contributing to higher rates of preventable mortality and prolonged hospita- lizations. In Italy, analysis of the currently available accreditation systems shows a substantial heteroge- neity of approaches for the prevention and surveillance of HAIs in hospitals. The aim of the present study is to develop and propose the use of a synthetic assessment tool that could be implemented homogenously throughout the nation. Methods. An analysis of nine international and of the 21 Italian regional accreditation systems was conducted in order to identify requirements a…

research product

[Legionella spp. contamination in indoor air: preliminary results of an Italian multicenter study].

Obiettivo. Rilevare la presenza di Legionella spp. nell’aria attraverso un protocollo standardizzato, a fianco dei tradizionali metodi impiegati per la rete idrica. Disegno. In dieci strutture sanitarie è stato selezionato un bagno, la cui acqua presentava una contaminazione da Legionella >1.000 unità formanti colonie (ufc)/litro. La contaminazione dell’aria è stata valutata tramite campionamento attivo (Surface Air System, SAS) e passivo, impiegando piastre di sedimentazione per la valutazione dell’Indice Microbico Aria (Index of Microbial Air, IMA). I campionamenti sono stati effettuati per 8 ore consecutive, a circa 1 m dal pavimento e a 50 cm dal rubinetto. Con il campionamento attivo, …

research product

A multidisciplinary approach to the study of cultural heritage environments: Experience at the Palatina Library in Parma

The aim of this paper is to describe a multidisciplinary approach including biological and particle monitoring, and microclimate analysis associated with the application of the Computational Fluid Dynamic (CFD). This approach was applied at the Palatina historical library in Parma. Monitoring was performed both in July and in December, in the absence of visitors and operators. Air microbial monitoring was performed with active and passive methods. Airborne particles with a diameter of ≥0.3, ≥0.5, ≥1 and ≥5 μm/m3, were counted by a laser particle counter. The surface contamination of shelves and manuscripts was assessed with nitrocellulose membranes. A spore trap sampler was used to identify…

research product

Riflessioni sulla didattica relativa all'insegnamento dell'Igiene Ospedaliera nei corsi di laurea delle professioni sanitarie

research product

Similarità ampelografiche tra ventuno accessioni minori autoctone della Campania

research product