0000000000335308

AUTHOR

J. M. Magraner

Automated Calculation Method to Determine the Output Power Based on the Frequency for Induction Heating IGBT Parallel Inverter

The fact that some inverter topologies used in induction heating applications allow the soft switching working operation lets the progressive replacement of the MOSFET with the IGBT in high power inverters. This is due to two main reasons, the former is the IGBT reliability and the latter is the ratio defined as the price of the component per output power. In this article an automated method to determine the output power based on the frequency of an inverter build with different IGBT is described. To carry out this method is necessary to define the power cycle and to develop the calculation process which determines the energy losses in the working conditions of the resonant parallel inverte…

research product

Using Pulse Density Modulation to Improve the Efficiency of IGBT Inverters in Induction Heating Applications

This paper analyses a high power (50 kW), high frequency (150 kHz) voltage fed inverter with a series resonant load circuit for industrial induction heating applications which is characterized by a full bridge inverter made with IGBT and the power control based on pulse density modulation (PDM). This power control strategy allows that the inverter works close to the resonance frequency for all output power levels. In this situation zero-voltage switching (ZVS) and zero-current switching (ZCS) conditions are performed and the switching losses are minimized. The results are verified experimentally using a prototype for induction hardening applications. A comparative study between the PDM and …

research product