Optical and visual quality comparison of implantable Collamer lens and laser in situ keratomileusis for myopia using an adaptive optics visual simulator.
Purpose. To compare optical and visual quality of the implantable Collamer lens (ICL) and laser in situ keratomileusis (LASIK) for myopia. Methods. An adaptive optics visual simulator (CRX1, Imagine Eyes, France) was used to simulate the vision after ICL implantation and LASIK procedure from the wavefront aberration pattern for -3 and -6 D. Monocular visual acuity (VA) at different contrasts and contrast sensitivity (CS) at 10, 20, and 25 cycles/degree (cpd) were measured for 3- and 5-mm pupils. Modulation transfer function (MTF) and point spread function (PSF) were calculated for a 5-mm pupil. Results. The ICL showed a MTF near of diffraction-limited MTF, but the post-LASIK of MTF worsened…
Optical quality of hyperopic and myopic phakic intraocular lenses
Aims: To assess and compare the optical quality of the myopic and hyperopic implantable collamer lens (ICL) from its wavefront aberrations for different powers and pupil diameters. Settings and Design: Prospective study. Material and Methods: The wavefront aberrations of two myopic (−3 and −6 diopters (D)) and two hyperopic V4b ICLs (+3 and +6D) were measured in vitro . To assess and compare the optical quality of different powers of ICLs, we analyzed the root mean square (RMS) of total higher order aberrations (HOAs), trefoil, coma, tetrafoil, secondary astigmatism, and spherical aberration at 3- and 4.5-mm pupil. In addition, the point spread functions (PSFs) of each ICL evaluated were ca…
Optical and Visual Quality of the Visian Implantable Collamer Lens Using an Adaptive-Optics Visual Simulator
To evaluate visual and optical quality of the implantable collamer lens for different powers and sizes of incision surgery.Prospective study in humans.An adaptive optics visual simulator was used to measure 3 powers of implantable collamer lenses and simulate the implantable collamer lens wavefront aberration's pattern for small- and large-incision surgery. Visual acuity (VA) and contrast sensitivity were measured in 11 observers for 3- and 5-mm pupils. Modulation transfer function, point spread function, and Strehl ratio were calculated.At 3 mm pupil, no statistically significant differences were found between both incision sizes for any implantable collamer lens power, except for -15 diop…
Assessment of corneal morphological changes induced by the use of daily disposable contact lenses.
To assess the effect of different disposable soft contact lenses upon corneal thickness, and upon anterior and posterior corneal curvatures using a dual-Scheimpflug imaging based device.Twenty-eight young, healthy subjects wore four different types of daily disposable soft contact lenses on four different days: Dailies Total1, Proclear 1 Day, Clariti 1-Day and 1-Day Acuvue Moist. The lenses had different material and water content. Pachymetry maps and keratometry values were obtained using the Galilei G4 twice a day: one before putting the lens on and one after an eight-hour period of contact-lens wear. Measurements were also recorded without any contact lenses being worn during a day.Clari…
Sensibilidad al contraste tras cirugía de cristalino transparente con lente intraocular multifocal asférica difractiva
PURPOSE: To evaluate distance and near contrast sensitivity (CS) under photopic and mesopic conditions before and after refractive lens exchange (RLE) and implantation of the aspheric AcrySof®ReSTOR® (SN6AD3 model) intraocular lens (IOL). METHODS:Seventy-four eyes of 37 patients after RLE underwent bilateral implantation with the aspheric AcrySof ReSTOR IOL. The patient sample was divided into myopic and hyperopic groups. Monocular uncorrected visual acuity at distance and near (UCVA and UCNVA, respectively) and monocular best corrected visual acuity at distance and near (BCVA and BCNVA, respectively) were measured before and 6 months postoperatively. Monocular CS function was measured at t…
Collagen copolymer posterior chamber phakic intraocular lens supported by the ciliary sulcus to treat myopia: One-year follow-up
Purpose To evaluate the predictability, stability, safety, and efficacy of Visian V4b Implantable Collamer Lens phakic intraocular lens (pIOL) implantation to treat varying degrees of myopia. Setting Fernandez-Vega Ophthalmological Institute, Oviedo, Spain. Design Prospective nonrandomized clinical study. Methods The uncorrected (UDVA) and corrected (CDVA) distance visual acuities, refraction, pIOL vault, and adverse effects were evaluated 12 months postoperatively. Results The study enrolled 121 eyes (68 patients). The mean spherical equivalent decreased from −8.61 diopters (D) ± 3.41 (SD) (range −18.75 to −2.25 D) preoperatively to −0.18 ± 0.29 D (range −1.25 to 0.50 D) 12 months postoper…
Assessment of modifications in thickness, curvatures, and volume upon the cornea caused by disposable soft contact lens wear.
Purpose To assess the effect of different disposable soft contact lenses on several corneal parameters–-thickness, anterior and posterior curvature, and volume–-by means of a Scheimpflug imaging-based device (Pentacam HR). Diurnal variations of these parameters were taken into account. Methods Twenty-one young, healthy subjects wore 4 different types of daily disposable soft contact lenses on 4 different days: Dailies AquaComfort Plus, SofLens, Dailies Total1, and Acuvue TruEye. The lenses had different material and water content. Pachymetry and curvature maps and corneal volume values were obtained using the Pentacam HR twice a day: one before putting the lens on and one after an 8-hour pe…
Visual simulation through different intraocular lenses using adaptive optics: Effect of tilt and decentration
Purpose To analyze visual quality differences between intraocular lenses (IOLs) and assess the impact of IOL decentration and tilt on visual quality. Setting University of Valencia, Valencia, Spain. Design Cohort study. Methods The crx1 adaptive optics visual simulator was used to simulate the wavefront aberration pattern of 2 commercially available aspheric aberration-correcting IOLs (Acrysof IQ SN60WF and Tecnis ZA9003) and 2 spherical IOLs (Akreos Adapt and Triplato) in 5 situations: centered, decentered 0.2 mm and 0.4 mm, and tilted 2 degrees and 4 degrees. Monocular distance visual acuity at 100%, 50%, and 10% contrast and the depth of focus were measured. Results Ten eyes of 10 patien…
Myopic astigmatism correction: comparison of a Toric Implantable Collamer Lens and a bioptics technique by an adaptive optics visual simulator.
Purpose To compare the optical and visual quality of a simulated Toric Implantable Collamer Lens (TICL) and a bioptics technique to treat high myopic astigmatism. Methods An adaptive optics visual simulator was used to simulate the vision after TICL implantation and a bioptics procedure from the wavefront aberration pattern for moderate and high-myopic astigmatism. Visual acuity (VA) at different contrasts and contrast sensitivity (CS) at 10, 20 and 25 cycles degree−1 were measured for 3 and 5-mm pupils. Modulation Transfer Function (MTF) and Point Spread Function (PSF) were calculated for a 5-mm pupil. Results At a 3-mm pupil we only found statistically significant differences in VA betwee…
Contrast sensitivity after refractive lens exchange with a multifocal diffractive aspheric intraocular lens
Purpose: To evaluate distance and near contrast sensitivity (CS) under photopic and mesopic conditions before and after refractive lens exchange (RLE) and implantation of the aspheric AcrySof ReSTOR (SN6AD3 model) intraocular lens (IOL) Methods: Sixty eyes of 30 consecutive patients after RLE underwent bilateral implantation with the aspheric AcrySof ReSTOR IOL. The patients sample was divided into myopic [n=15, mean spherical equivalent (SE) -6.87± 2.03 diopters (D)] and hyperopic (n=15, mean SE +4.52±1.14 D) groups. Monocular uncorrected visual acuity at distance and near (UCVA and UCNVA, respectively) and monocular best corrected visual acuity at distance and near (BCVA and BCNVA, respec…
Optical and Visual Simulation of Standard and Modified Spherical Aberration Implantable Collamer Lens Post Myopic LASIK Surgery
To evaluate the visual quality achieved in patients undergoing standard or modified implantable Collamer lens (ICL) to correct residual myopic error after laser-assisted in situ keratomileusis (LASIK) surgery.The adaptive optics visual simulator was used to simulate LASIK surgery of moderate and high myopia with a myopic regression corrected by a standard and modified ICL. Visual acuity (VA) and contrast sensitivity (CS) were measured in 14 subjects at 3- and 4.5-mm pupil. Point spread function and simulated retinal images were calculated.Comparing LASIK plus standard ICL and LASIK plus modified ICL simulations, for moderate myopia, VA improvement was less than 1 line in all VA contrasts an…
Optical Quality Comparison of Conventional and Hole-Visian Implantable Collamer Lens at Different Degrees of Decentering
To compare the optical quality of implantable Collamer lens (ICL) with and without central hole (Hole ICL and conventional ICL) at different degrees of decentering.Experimental laboratory investigation.Wavefront aberrations of the -3, -6, and -12 diopter (D) V4b and -3, -6, and -12 D V4c ICLs were measured in 3 conditions-centered and decentered 0.3 and 0.6 mm-at 3-mm and 4.5-mm pupils. The root mean square of total higher order aberrations, trefoil, coma, tetrafoil, secondary astigmatism, and spherical aberration were evaluated. In addition, point spread function and simulated retinal images of ICLs were calculated from the wavefront aberrations for each ICL and all conditions of decenteri…
Prevalence of cataract after collagen copolymer phakic intraocular lens implantation for myopia, hyperopia, and astigmatism
Purpose To evaluate the prevalence of cataract after Implantable Collamer Lens phakic intraocular lens (pIOL) implantation with different models at different ages and for different refractive powers. Setting Fernandez-Vega Ophthalmological Institute, Oviedo, Spain. Design Retrospective nonrandomized clinical study. Methods The pIOL (models V4, V4b, or V4c) was implanted in all cases. Results The study included 3420 eyes (1898 patients). The mean patient age at surgery was 31.2 years ± 6.4 (SD) (range 18 to 50 years) and the mean spherical refractive error, −7.27 ± 5.24 diopters (D) (range −26.5 to 12.5 D). Twenty-one eyes (0.61%) of 15 patients had pIOL explantation (all model V4) because c…
Depth of focus through different intraocular lenses in patients with different corneal profiles using adaptive optics visual simulation
PURPOSE: To evaluate the depth of focus with monofocal intraocular lenses (IOLs) in patients with different corneal profiles using adaptive optics (AO) visual simulation. METHODS: An AO visual simulator (crx1, Imagine Eyes) was used to simulate the aberration pattern of three monofocal IOLs (Acrysof IQ SN60WF [Alcon Laboratories Inc]; Akreos Adapt AO [Bausch & Lomb]; and Triplato [AJL Ophthalmic]) of different optic designs. Five groups were considered: patients without any corneal refractive surgery (normal cornea group) and with prior low and high myopic and hyperopic ablations (low myopic ablation, high myopic ablation, low hyperopic ablation, and high hyperopic ablation groups). De…
In vitro optical performance of nonrotational symmetric and refractive-diffractive aspheric multifocal intraocular lenses: impact of tilt and decentration.
Purpose To evaluate the optical quality of Acrysof Restor SN6AD1 refractive–diffractive +3.00 D and Lentis Mplus LS-312 nonrotational symmetric +3.00 D aspheric multifocal intraocular lenses (IOLs) and analyze the effect of tilt and decentration. Setting University of Valencia, Valencia, and University of Murcia, Murcia, Spain. Design Experimental study. Methods An artificial model eye was used to measure wavefront aberrations of both IOL models. The modulation transfer function (MTF) and point-spread function (PSF) were calculated for a 5.0 mm pupil and under 5 situations: centered, 0.2 mm and 0.4 mm decentered, and 2 degrees and 4 degrees tilted. Results The refractive–diffractive IOL had…
Device interchangeability on anterior chamber depth and white-to-white measurements: a thorough literature review
We have reviewed a set of recently published studies that compared the anterior chamber depth (ACD) and/or white-to-white (WTW) distance obtained by means of different measuring devices. Since some of those studies reached contradictory conclusions regarding device interchangeability, this review was carried out in attempting to clarify which clinical devices can or cannot be considered as interchangeable in clinical practice to measure ACD and/or WTW distance, among these devices: A-scan, ultrasound biomicroscopy, Orbscan and Orbscan II (Bausch&Lomb Surgical Inc., San Dimas, California, USA), Pentacam and Pentacam HR (Oculus, Wetzlar, Germany), Galilei (Ziemer, Switzerland), Visante optica…
Implantable collamer lens and femtosecond laser for myopia: comparison using an adaptive optics visual simulator.
Purpose: To compare optical and visual quality of implantable collamer lens (ICL) implantation and femtosecond laser in situ keratomileusis (F-LASIK) for myopia. Methods: The CRX1 adaptive optics visual simulator (Imagine Eyes, Orsay, France) was used to simulate the wavefront aberration pattern after the two surgical procedures for -3-diopter (D) and -6-D myopia. Visual acuity at different contrasts and contrast sensitivities at 10, 20, and 25 cycles/degree (cpd) were measured for 3-mm and 5-mm pupils. The modulation transfer function (MTF) and point spread function (PSF) were calculated for 5-mm pupils. Results: F-LASIK MTF was worse than ICL MTF, which was close to diffraction-limited MT…
Five-year functional outcomes and vault of -20 diopter myopic phakic intraocular lens implantation.
Purpose To evaluate refractive and visual outcomes and complications associated with phakic intraocular lens (pIOL) implantation to correct high myopia. Settings Fernandez-Vega Ophthalmological Institute, Oviedo, Spain. Design Retrospective observational case series. Methods Uncorrected distance visual acuity (UDVA) and corrected distance visual acuity (CDVA), refraction, vault, and adverse effects were evaluated after 5 years with Visian ICMV4 pIOL. Results Mean spherical equivalent (SE) dropped from −18.32 ± 2.37 diopters (D) preoperatively to −0.88 ± 0.52D 5 years postoperatively; 61% of eyes were within ±0.75 D of the target. The mean Snellen decimal CDVA and UDVA were 0.73 ± 0.23 and 0…
Optical quality comparison between 2 collagen copolymer posterior chamber phakic intraocular lens designs
Purpose To compare the optical quality in vitro of 2 designs of the Visian Implantable Collamer Lens phakic intraocular lens (pIOL) for different powers and optical apertures. Setting University of Valencia, Valencia, Spain. Design Experimental study. Methods The Nimo TR1504 deflectometry device was used to measure the V4c pIOL, which has a smaller optic diameter, and the V5 pIOL, which has a larger optic diameter. The pIOLs were measured for −3.00 diopters (D), −6.00 D, −9.50 D, and −10.50 D at different optical apertures from 3.00 to 6.00 mm depending on the IOL power and model. The root mean square of higher-order aberrations (RMS HOAs) was analyzed. The Strehl ratio, point-spread functi…
The effect of simulated normal and amblyopic higher-order aberrations on visual performance.
Purpose To study the effect of simulated amblyopic and normal higher-order aberrations on visual performance of normal eyes. Methods To assess visual function, an adaptive optics visual simulator was used to compensate volunteers' ocular aberrations and simulate the wavefront aberration patterns found in healthy and amblyopic eyes in 7 healthy individuals. Visual acuity for high (100%), medium (50%), and low (10%) contrast and contrast sensitivity at 10, 20, and 25 cycles per degree (cpd) were measured after simulation of both pattern aberrations. The modulation transfer function and the point spread function were computed based on the aberration data. All measures were taken for 3 and 5.5 …
Crystalens HD Intraocular Lens Analysis Using an Adaptive Optics Visual Simulator
PURPOSE To compare visual and optical quality of the Crystalens HD intraocular lens (IOL) with that of a monofocal IOL. METHODS The wavefront aberration patterns of the monocular Akreos Adapt AO IOL and the single-optic accommodating Crystalens HD IOL were measured in a model eye. The Crystalens IOL was measured in its nonaccommodative state and then, after flexing the haptic to produce 1.4 mm of movement, in its accommodative state. Using an adaptive optics system, subjects' aberrations were removed and replaced with those of pseudophakes viewing with either lens. Monocular distance visual acuity (DVA) at high (100%), medium (50%), and low (10%) contrast and contrast sensitivity (CS) were …
Interchangeability among five devices that measure anterior eye distances.
The aim was to study the interchangeability of various devices that measure anterior chamber depth (ACD) and white-to-white (WTW) distance.Eighty right eyes of eighty patients aged 20 to 40 years were included. Their spherical equivalent ranged from -4.25 to +1.00 dioptres. Each eye's ACD and the WTW distance were measured using the following devices: a Castroviejo surgical calliper, CA-200F Corneal Analyser, Orbscan II, Pentacam HR and IOLMaster 500.The Pentacam HR measured significantly greater ACD (p0.01) than the other two devices, whereas IOLMaster 500 and Orbscan II yielded comparable (p0.01) distances. Nonetheless, in every device comparison, the mean difference was within clinically…
Visual quality comparison of conventional and Hole-Visian implantable collamer lens at different degrees of decentering
Purpose To compare the visual quality of implantable collamer lens (ICL) with and without central hole (Hole ICL and conventional ICL) at different degrees of decentering. Methods An adaptive optics visual simulator (crx1, Imagine Eyes, Orsay, France) was used to simulate the –3, –6 and –12 dioptres (D) conventional and Hole ICLs in three conditions: centred and decentred 0.3 and 0.6 mm. Visual acuity (VA) at high-contrast, medium-contrast and low-contrast and contrast sensitivity (CS) were measured in 15 observers for 3 and 4.5 mm pupils. Results No statistically significant differences in VA and CS were found between conventional and Hole ICLs for any ICL powers and pupil sizes evaluated …
Simulated prototype of posterior chamber phakic intraocular lens for presbyopia correction.
Purpose To evaluate the visual impact of adding different spherical aberration values to an Implantable Collamer Lens phakic intraocular lens (pIOL) to increase the depth of focus using an adaptive optics visual simulator. Setting University of Valencia, Valencia, Spain. Design Experimental study. Methods Wavefront aberrations in −3.00 D and −6.00 diopter (D) pIOLs were measured in vitro. Afterward, different simulated pIOL experimental prototypes were created along with variances in the spherical aberration. An adaptive optics visual simulator was used to simulate vision after the implantation of the different pIOL prototypes from their wavefront aberrations. The corrected distance visual …
Optical Quality Comparison between Spherical and Aspheric Toric Intraocular Lenses
Purpose To measure and compare the optical quality of spherical and aspheric toric intraocular lenses (IOLs). Methods Wavefront aberrations of AcrySof Toric and IQ Toric IOLs (Alcon Laboratories) for different powers were measured at 3- and 5-mm pupils by Nimo TR0805 instrument. The Zernike coefficients of trefoil, coma, tetrafoil, secondary astigmatism, and spherical aberration were evaluated. The point spread functions (PSFs) of each IOL evaluated were calculated from the wavefront aberrations. The PSF images also were calculated from the IOL wavefront aberrations, adding the cornea's aberrations to simulate the optical quality after their implantation. Results Spherical toric IOLs showed…
Implantable collamer lens and femtosecond laser for myopia: comparison using an adaptive optics visual simulator
Purpose: To compare optical and visual quality of implantable collamer lens (ICL) implantation and femtosecond laser in situ keratomileusis (F-LASIK) for myopia. Methods: The CRX1 adaptive optics visual simulator (Imagine Eyes, Orsay, France) was used to simulate the wavefront aberration pattern after the two surgical procedures for -3-diopter (D) and -6-D myopia. Visual acuity at different contrasts and contrast sensitivities at 10, 20, and 25 cycles/degree (cpd) were measured for 3-mm and 5-mm pupils. The modulation transfer function (MTF) and point spread function (PSF) were calculated for 5-mm pupils. Results: F-LASIK MTF was worse than ICL MTF, which was close to diffraction-limited MT…