0000000000349243

AUTHOR

Karl Martin Lehmann

showing 3 related works from this author

Marginal and Internal Precision of Zirconia Four-Unit Fixed Partial Denture Frameworks Produced Using Four Milling Systems

2021

Background: CAD/CAM systems enable the production of fixed partial dentures with small and reproducible internal and marginal gaps. Purpose: The purpose of this study was to evaluate the reproducibility of the marginal and internal adaptations of four-unit fixed partial denture frameworks produced using four CAD/CAM systems. Materials and Methods: Prepared dies of a master model that simulated the loss of the first left molar were measured. Fifteen frameworks were manufactured using four CAD/CAM systems (A–D). The internal fit was determined by the replica technique, and the marginal gap was determined by microscopy. ANOVA was carried out to detect significant differences, and the Bonferron…

Molarinternal fitTechnologyCAD02 engineering and technologySystem aArticleCAD/CAM03 medical and health sciencessymbols.namesake0302 clinical medicineFixed partial denturesGeneral Materials ScienceMathematicsOrthodonticsReproducibilityMicroscopyQC120-168.85TQH201-278.5030206 dentistry021001 nanoscience & nanotechnologyEngineering (General). Civil engineering (General)TK1-9971Bonferroni correctionDescriptive and experimental mechanicsFPDsymbolsmarginal fitElectrical engineering. Electronics. Nuclear engineeringTA1-20400210 nano-technologyzirconiaMaterials
researchProduct

Sensitivity and Specificity of Stability Criteria for Immediately Loaded Splinted Maxillary Implants

2014

Background To assess the suitability of dental implants for immediate loading, primary stability is usually evaluated intraoperatively. Purpose This retrospective study aimed to assess the suitability of three stability parameters – namely, insertion torque (IT), implant stability quotient (ISQ; measured by resonance frequency analysis), and Periotest (PT) values – as potential predictors for the risk of nonosseointegration of immediately loaded splinted implants. The stability parameters were routinely collected under immediate loading. Materials and Methods Nineteen patients with 11 edentulous and 8 partially edentulous maxillae were treated with 105 dental implants, which were immediatel…

business.industrymedicine.medical_treatmentArea under the curveDentistryAnatomyImplant stability quotientOsseointegrationResonance frequency analysisMaxillaImmediate loadingmedicineImplantOral SurgeryDenturesbusinessGeneral DentistryClinical Implant Dentistry and Related Research
researchProduct

Four color-measuring devices compared with a spectrophotometric reference system

2009

Abstract Objectives The objective of this study was to compare the L*C*h° color coordinates of dental color-measuring devices with those of a spectrophotometric reference system. Methods The International Commission on Illumination (CIE) L*C*h° color coordinates of ceramic samples, matching the colors of the VITA Linearguide, were recorded using four color-measuring devices (VITA Easyshade (A), VITA Easyshade compact (B), Degudent Shadepilot (C), X-Rite Shadevision (D)) and a spectrophotometric reference system under standardized test conditions. The intraclass correlation coefficients, regression lines with coefficients of determination, and mean deviations of the dental color-measuring de…

medicine.diagnostic_testProsthesis ColoringIntraclass correlationAnalytical chemistryColorReproducibility of ResultsRepeatabilityDental Prosthesis DesignSpectrophotometrySpectrophotometryLinear regressionLinear ModelsmedicineMeasuring instrumentHumansTooth DiscolorationColorimetryColorimetryGeneral DentistryColor coordinatesHueMathematicsJournal of Dentistry
researchProduct