0000000000349244

AUTHOR

Stefan Wentaschek

showing 3 related works from this author

Marginal and Internal Precision of Zirconia Four-Unit Fixed Partial Denture Frameworks Produced Using Four Milling Systems

2021

Background: CAD/CAM systems enable the production of fixed partial dentures with small and reproducible internal and marginal gaps. Purpose: The purpose of this study was to evaluate the reproducibility of the marginal and internal adaptations of four-unit fixed partial denture frameworks produced using four CAD/CAM systems. Materials and Methods: Prepared dies of a master model that simulated the loss of the first left molar were measured. Fifteen frameworks were manufactured using four CAD/CAM systems (A–D). The internal fit was determined by the replica technique, and the marginal gap was determined by microscopy. ANOVA was carried out to detect significant differences, and the Bonferron…

Molarinternal fitTechnologyCAD02 engineering and technologySystem aArticleCAD/CAM03 medical and health sciencessymbols.namesake0302 clinical medicineFixed partial denturesGeneral Materials ScienceMathematicsOrthodonticsReproducibilityMicroscopyQC120-168.85TQH201-278.5030206 dentistry021001 nanoscience & nanotechnologyEngineering (General). Civil engineering (General)TK1-9971Bonferroni correctionDescriptive and experimental mechanicsFPDsymbolsmarginal fitElectrical engineering. Electronics. Nuclear engineeringTA1-20400210 nano-technologyzirconiaMaterials
researchProduct

Sensitivity and Specificity of Stability Criteria for Immediately Loaded Splinted Maxillary Implants

2014

Background To assess the suitability of dental implants for immediate loading, primary stability is usually evaluated intraoperatively. Purpose This retrospective study aimed to assess the suitability of three stability parameters – namely, insertion torque (IT), implant stability quotient (ISQ; measured by resonance frequency analysis), and Periotest (PT) values – as potential predictors for the risk of nonosseointegration of immediately loaded splinted implants. The stability parameters were routinely collected under immediate loading. Materials and Methods Nineteen patients with 11 edentulous and 8 partially edentulous maxillae were treated with 105 dental implants, which were immediatel…

business.industrymedicine.medical_treatmentArea under the curveDentistryAnatomyImplant stability quotientOsseointegrationResonance frequency analysisMaxillaImmediate loadingmedicineImplantOral SurgeryDenturesbusinessGeneral DentistryClinical Implant Dentistry and Related Research
researchProduct

Interradicular Root Canals in Mandibular First Molars: A Literature Review and Ex Vivo Study

2019

Abstract Introduction Successful endodontic treatment vastly depends to a high degree on an accurate knowledge of root canal system morphology. It is a prerequisite to be aware of all possible reservoirs where bacteria and/or toxins can persist, compromising the surrounding tissues; such knowledge results in endodontic success. Methods The presence of interradicular canals and diverticula between the pulp chamber floor and the bifurcation area surface of 117 mandibular first molars was investigated. Access cavities were prepared, the teeth were embedded in plastic, and the pulp chambers were flooded with methylene blue and then centrifuged. An average of 4.2 (0.145 ± 0.03 mm thickness) slic…

0301 basic medicineMolarRoot canalDentistryMandibleChemical cleaningTreatment failure03 medical and health sciences0302 clinical medicinestomatognathic systemmedicineHumansGeneral DentistryMicroscopybusiness.industryClinical performanceA diamond030206 dentistryMolarRoot Canal Therapystomatognathic diseases030104 developmental biologymedicine.anatomical_structurePulp (tooth)Dental Pulp CavitybusinessJournal of Endodontics