0000000000354599

AUTHOR

B. Martin Eicke

Comparison of the sympathetic skin response and continuous wave Doppler sonography of the radial artery.

The value of neurophysiological tests of the autonomic nerve system is limited. One of the clinically most commonly applied test is the skin sudomotor response, frequently referred to as 'sympathetic skin response' (SSR). However, the SSR is a more qualitative than quantitative evaluation technique. Continuous wave (cw) Doppler sonography of the radial artery may be an alternative quantitative approach. We studied 41 age matched volunteers (23 female, 18 male; 16-82 years (mean age 53 years)). The stimulus was a loud and unexpected acoustic signal, alternatively a cough. SSR evaluation included the latency of onset, the duration and the amplitude of the response. Doppler evaluation also inc…

research product

Extracranial internal carotid artery occlusion: the role of common carotid artery volume flow.

BACKGROUND AND PURPOSE Quantitative measurement of blood flow volume in the common carotid artery (CCA) is now possible using the color velocity imaging quantification (CVI-Q) ultrasound technique. The aim of this study was to evaluate the cerebral hemodynamic effects of unilateral internal carotid artery (ICA) occlusion on CCA blood flow volumes (FVs) using CVI-Q. METHODS Records of ultrasound studies in our neurosonology laboratory were retrospectively reviewed to identify patients with unilateral ICA occlusions who at a minimum received both a routine color duplex carotid ultrasound examination and quantitative measurement of FV in the CCA, bilaterally, using the CVI-Q method. A total of…

research product

Low-frequency ultrasound induces nonenzymatic thrombolysis in vitro.

To evaluate whether ultrasound, applied over a distance of several centimeters and in the absence of thrombolytic agents, may have a thrombolytic effect on blood clots.Low-frequency (20 kHz) continuous wave ultrasound at different intensity levels (0.15-1.2 W/cm2) and exposure times (5, 10, and 20 minutes) was assessed for its potential to induce thrombolysis of fresh human blood clots. The ultrasound effect was also studied in combination with recombinant tissue-type plasminogen activator-mediated thrombolysis. Experiments were carried out in a flow model in degassed sodium phosphate buffer at 37 degrees C at a distance of 3 cm from the ultrasonic probe to the blood clots. Regardless of ul…

research product

Ultrasound-induced blood clot dissolution without a thrombolytic drug is more effective with lower frequencies.

<i>Background and Purpose:</i> Therapeutic ultrasound as stand-alone therapy or in combination with rt-PA has proven to be an effective measure for recanalisation of acute vessel occlusion in different in vitro and in vivo studies. Uncertainty still exists concerning the optimal frequency and intensity with regard to the thrombolytic efficacy of ultrasound. The purpose of this study was a direct comparison of different ultrasound frequencies, when otherwise using identical measurement settings and parameters. <i>Methods:</i> Ultrasound-induced dissolution of fresh human blood clots was studied in a flow system using low-frequency continuous wave ultrasound of 20, 40 …

research product

Color-coded duplex ultrasonography of the origin of the vertebral artery: normal values of flow velocities.

The introduction of color-coded duplex ultrasonography has improved the ease of performing ultrasound investigations of the vertebral arteries. So far, normal values of flow velocities have been reported only for the intertransverse region of the vertebral artery (V2 segments). Atherosclerotic disease at the origin of the vertebral arteries (V0 segment) is frequent and is one of the risk factors for vertebrobasilar ischemic disease. Normal values of flow velocities of the vertebral artery origin are needed to assess pathologic findings, such as vertebral artery origin stenosis or dissection. The aim of this study was to describe the normal flow velocities of vertebral artery origin (V0 segm…

research product

Ultraschallkontrastmittel Levovist ® steigert den thrombolytischen Effekt von niederfrequentem Ultraschall

Hintergrund: Die therapeutische Anwendung von Ultraschall zur Rekanalisation eines akuten thrombotischen oder embolischen Gefasverschlusses stellt eine vielversprechende Alternative bzw. Erganzung existierender Therapieoptionen dar. Neuere Studien belegen eine thrombolytische Effizienz von Ultraschall in alleiniger Anwendung und in Kombination mit rr-PA. Ziel dieser Studie war es, zu untersuchen, ob sich durch Zugabe des Ultraschallkontrastmittels Levovist® eine Steigerung der ultraschallinduzierten Thrombolyse erreichen lasst.

research product

Cerebral embolic ischemia in rats: correlation of stroke severity and functional deficit as important outcome parameter.

The embolic MCA occlusion model in rats is used for recanalisation studies in acute stroke. In addition to the determination of lesion size, the assessment of functional outcome may improve the value of this model. Male Wistar rats were submitted to MCA clot embolism or sham surgery. In order to achieve a larger variety of lesion volume, 2 subgroups (each 7 animals) were subjected to differently sized emboli (30 and 40 mm). Follow-up period was 6 days. Outcome assessment consisted of a test battery including parallel bar crossing, observation of behaviour in an open field and an 8-arm maze and a neurological score with ten different sensorimotor and coordinative items. Animals were perfusio…

research product