0000000000359071

AUTHOR

F Krummenauer

Transpalpebral tonometry: reliability and comparison with Goldmann applanation tonometry and palpation in healthy volunteers

Background/aim: TGDc-01 is a new, portable, transpalpebral tonometry device. The aim of this study was to evaluate the reproducibility of this method, including intraobserver and interobserver deviations, and to compare the results with those of Goldmann applanation tonometry and palpation of intraocular pressure (IOP). Methods: A total of 40 eyes of 20 healthy volunteers were included. Two independent parallel observers (1 and 2) performed three replicate measurements per eye, respectively, both using TGDc01 tonometry, one observer (3) performed three replicate measurements using Goldmann applanation tonometry, and one observer (4) measured the IOP via palpation. Intraindividual deviations…

research product

Assessment of proliferative activity in breast cancer: MIB-1 immunohistochemistry versus mitotic figure count.

Abstract The proliferative activity is one of the most important single prognostic parameters in breast cancer diagnosis and the time-honored measure of proliferative activity, the mitotic figure count, is an integral component of most combined prognostic scores. The detection of the cell cycle-specific antigens Ki-67, and the development of anti-Ki-67 antibodies, including the paraffin-reactive antibody MIB-1, have established immunohistochemical detection of cell cycle-specific antigens as a measure of proliferative activity in breast cancer diagnosis. The current study was performed to correlate mitotic figure counts with the proliferative activity as assessed by MIB-1 immunohistochemist…

research product

Somatostatin-receptor scintigraphy in Graves' disease: reproducibility and variance of orbital activity.

Somatostatin-receptor (SSTR) scintigraphy using the single photon emission computed tomography (SPECT) technique allows the assessment of orbital inflammation in patients with Graves' disease. Previous studies showed differences in orbital octreotide uptake already 4 hr after injection. In this study, analysis of inter-/intra-observer variance and reproducibility in the evaluation of orbital SPECT images was performed. First, SPECT data of one representative female patient with clinically active Graves' ophthalmopathy (GO), obtained 4 hr after intravenous injection of 110 MBq 111In-pentetreotide and processed by filtered backprojection, were analyzed. Transverse SPECT images were reconstruc…

research product

Artificial ventilation for basic life support leads to hyperventilation in first aid providers.

The 'Guidelines 2000 for Cardiopulmonary Resuscitation and Emergency Cardiovascular Care - International Consensus on Science' recommend an artificial ventilation volume of 10 ml/kg bodyweight (equivalent to a tidal volume of 700-1000 ml) without the use of supplemental oxygen in adults with respiratory arrest. For first aid providers using the mouth-to-mouth or mouth-to-nose-ventilation technique, respectively, a ventilation volume of approximately 9.6 l/min results. Additionally, a deep breath is recommended before each ventilation to increase the end-expiratory oxygen concentration of the air exhaled by the first aid provider. To investigate the effects of these recommendations in health…

research product