0000000000362002

AUTHOR

Norberti Bernardineli

showing 2 related works from this author

Analysis of the physicochemical properties, cytotoxicity and volumetric changes of AH Plus, MTA Fillapex and TotalFill BC Sealer

2020

Background To evaluate the physicochemical properties and cytotoxicity of AH Plus, MTA Fillapex and TotalFill BC Sealer. Volumetric changes were also evaluating using micro-computed tomography (micro-CT). Material and Methods Radiopacity and flow were evaluated in accordance with the ISO 6876, while setting time was evaluated in accordance with the ASTM- C266-08 specifications. The release of Ca2+ ions and pH were measured with spectrophotometer and pH meter, respectively, after different time intervals (1h, 3h, 24h, 72h, 168h, and 360h). Cytotoxicity was evaluated by MTT reduction assay to check 3T3 cells viability at 24, 48 and 72 hours. Volumetric change was evaluated by micro-CT, by usi…

Ion releaseChemistryMicro computed tomographyRoot canalRadiodensityResearch030209 endocrinology & metabolism030206 dentistryRADIOPACIDADE:CIENCIAS MÉDICAS [UNESCO]pH meterOperative Dentistry and Endodontics03 medical and health sciences0302 clinical medicinemedicine.anatomical_structureDistilled waterMTA-FillapexUNESCO::CIENCIAS MÉDICASmedicineCytotoxicityGeneral DentistryNuclear chemistryJournal of Clinical and Experimental Dentistry
researchProduct

Efficacy of the NaviTip FX irrigation needle in removing calcium hydroxide from root canal

2012

Objective: To evaluate the effectiveness of the NaviTip FX, brush-covered irrigation needle, in removing calcium hydroxide from the root canal. Study Design: Thirty single-rooted teeth were randomly divided into three groups: A - irrigation with a hypodermic needle inserted as far as possible without binding and activation with #30 K-type file; B - Irrigation with a hypodermic needle without activation; C - irrigation with NaviTip FX needle. Sodium hypoclorite 1% was used in irrigation. The root canals were examined trough scanning electron microscopy. Calcium hydroxide removal was recorded at 1, 5, and 10mm from the working length (WL) and the data were analysed using one-way ANOVA test (p…

IrrigationCalcium hydroxideMICROSCOPIA ELETRÔNICAbusiness.industryResearchRoot canalSignificant differenceAnova testLower scoreSmear layerDentistryOdontología:CIENCIAS MÉDICAS [UNESCO]Ciencias de la saludchemistry.chemical_compoundmedicine.anatomical_structurechemistryClinical and Experimental DentistryUNESCO::CIENCIAS MÉDICASmedicinebusinessGeneral DentistryHypodermic needle
researchProduct