0000000000364834

AUTHOR

P. Sattelberger

Trace Analysis of Plutonium and Technetium by Resonance Ionization Mass Spectrometry Using an Atomic Beam and a Laser Ion Source

A method for low level detection of plutonium and technetium is described with a detection limit of less than 107 atoms. Plutonium is a very toxic element due to its radioactive decay as well as its chemical behaviour. It was released to the environment in large amounts during the fifties and sixties of his century, principally by nuclear-weapon tests and some accidents. As a result about 0.4 − 4 mBq per gram 239Pu(T1/2 = 24390 y), corresponding to 4 × 108 − 4 × 109 atoms, can be found in the Northern Hemisphere in soil samples.

research product

Trace detection of plutonium by three-step photoionization with a laser system pumped by a copper vapor laser

Laser photoionization has been used to detect trace amounts of plutonium. A high sensitivity and selectivity has been achieved by applying three-step excitation and ionization of the plutonium atoms with high pulse-repetition rates and additional mass determination by time-of-flight measurements. A laser system was developed which consists of a copper vapor laser pumping three dye lasers simultaneously. Samples containing between 1010 and 1012 atoms of239Pu on Re filaments were measured yielding strong resonance signals with maximum ion count rates of several kHz at a vanishingly low background. A detection efficiency of 10−7 was determined allowing the detection of about 108 plutonium atom…

research product

Resonance ionization mass spectroscopy for trace analysis of neptunium

Resonance ionization mass spectroscopic (RIMS) measurements for trace analysis and spectroscopy of 237Np, the ecologically most important isotope of neptunium, are described. The chemical procedure for the separation of neptunium from aqueous samples as well as the preparation of filaments for RIMS are outlined. Several two- and three-step excitation schemes have been investigated in order to find suitable conditions for the sensitive detection of 237Np. Using a three-step, three-color excitation and ionization scheme an overall detection efficiency of 3×10−8 was obtained, resulting in a detection limit of 4×108 atoms (160 fg) of 237Np. The hyperfine structure splittings of the levels under…

research product

Determination of trace elements by resonant ionization mass spectrometry (RIMS)

A resonant ionization mass spectrometer has been developed as an analytical tool for the detection of trace elements, especially of plutonium and other radionuclides. The sample, deposited on a rhenium filament, is evaporated by electrical heating and the atoms of the element under investigation are selectively ionized by laser light delivered from three dye lasers pumped by a copper vapour laser. The resulting photoions are detected in a time-of-flight spectrometer with a channelplate detector. For plutonium a mass resolution of M/δM=1500 was obtained and an overall detection efficiency of 4×10−6 was determined for stepwise excitation and ionization via autoionizing states. With a laser li…

research product