Trace detection of plutonium by three-step photoionization with a laser system pumped by a copper vapor laser
H. RimkeP. PeuserJ. BonnErnst W. OttenW. RusterP. SattelbergerGünter HerrmannNorbert TrautmannU. KrönertF. AmesH.-j. Klugesubject
Copper vapor laserDye laserMaterials sciencePhysics and Astronomy (miscellaneous)General EngineeringPhotoionization modeGeneral Physics and Astronomychemistry.chemical_elementPhotoionizationLaserlaw.inventionPlutoniumchemistrylawIonizationPhysics::Atomic PhysicsAtomic physicsAtomic vapor laser isotope separationdescription
Laser photoionization has been used to detect trace amounts of plutonium. A high sensitivity and selectivity has been achieved by applying three-step excitation and ionization of the plutonium atoms with high pulse-repetition rates and additional mass determination by time-of-flight measurements. A laser system was developed which consists of a copper vapor laser pumping three dye lasers simultaneously. Samples containing between 1010 and 1012 atoms of239Pu on Re filaments were measured yielding strong resonance signals with maximum ion count rates of several kHz at a vanishingly low background. A detection efficiency of 10−7 was determined allowing the detection of about 108 plutonium atoms in a sample.
year | journal | country | edition | language |
---|---|---|---|---|
1985-12-01 | Applied Physics B Photophysics and Laser Chemistry |