0000000000372414

AUTHOR

M. Pindo

Updated precision measurement of the average lifetime of B hadrons

The measurement of the average lifetime of B hadrons using inclusively reconstructed secondary vertices has been updated using both an improved processing of previous data and additional statistics from new data. This has reduced the statistical and systematic uncertainties and gives \tau_{\mathrm{B}} = 1.582 \pm 0.011\ \mathrm{(stat.)} \pm 0.027\ \mathrm{(syst.)}\ \mathrm{ps.} Combining this result with the previous result based on charged particle impact parameter distributions yields \tau_{\mathrm{B}} = 1.575 \pm 0.010\ \mathrm{(stat.)} \pm 0.026\ \mathrm{(syst.)}\ \mathrm{ps.}

research product

Performance of the DELPHI detector

DELPHI (DEtector with Lepton, Photon and Hadron Identification) is a detector for e(+)e(-) physics, designed to provide high granularity over a 4 pi solid angle, allowing an effective particle identification, It has been operating at the LEP (Large Electron-Positron) collider at CERN since 1989. This article reviews its performance.

research product

Search for exclusive decays of the Lambda_b baryon and measurement of its mass

A search for fully reconstructed \lb beauty baryons is performed using about 3 million Z decays collected with the DELPHI detector at LEP. The analysis relies on the combined use of the accurate tracking and of the hadron identification capabilities of DELPHI. A total of four events has been found, three in the \lc\ppm channel and one in the \lc\a1m channel over a small background. The \lb beauty baryon mass is measured to be (~ 5668 \pm 16~ ({\rm stat.}) \pm 8~({\rm syst.})~)~ \mv.

research product

First measurement of f′2 (1525) production in Z0 hadronic decays

The inclusive production of the f(2)'(1525) in hadronic Z(0) decays has been studied in data collected by the DELPHI detector at LEP. The Ring Imaging Cherenkov detectors were important tools in the identification of the decay f(2)'(1525) --> K+K-. The average number of f(2)(')(1525) produced per hadronic Z decay, [f(2)'] = 0.020 +/- 0.005 (stat) +/- 0.006 (syst), and the momentum distribution of the f(2)'(1525) have both been measured. The mass and width of the f(2)'(1525) are found to be [M(f2)'] = 1535 +/- 5 (stat) +/- 4 (syst) MeV/c(2). [Gamma(f2)'] = 60 +/- 20 (stat) +/- 19 (syst) MeV/c(2)

research product

Search for promptly produced heavy quarkonium states in hadronic Z decays

A search has been made for direct production of heavy quarkonium states in more than 3 million hadronic Z^{0} decays in the 1991-1994 DELPHI data. Prompt J/\psi, \psi(2S) and \Upsilon candidates have been searched for through their leptonic decay modes using criteria based on the kinematics and decay vertex positions. New upper limits are set at the 90 \% confidence level for {Br( Z^0 \rightarrow \left( Q \bar{Q} \right) X ) / Br( Z^0 \rightarrow \mbox{hadrons})} for various strong production mechanisms of J/\psi and \Upsilon; these range down to 0.9 \times 10^{-4}. The limits are set in the presence of a small excess (\sim 1 \% statistical probability of a background fluctuation) in the su…

research product

A Precise Measurement of the Tau Lepton Lifetime

The tau lepton lifetime has been measured using three different methods with the DELPHI detector. Two measurements of one-prong decays are combined, accounting for correlations, giving a result of \tau_\tau = 291.8 \pm 3.3 \mbox{ (stat.)} \pm 2.0 \mbox{(sys.) fs} while the decay length distribution of three-prong decays gives the result \tau_{\tau} = 286.7 \pm 4.9 \mbox{ (stat.)} \pm 3.3 \mbox{ (sys.) fs}. Combining the results presented here with previous DELPHI measurements, we get \tau_{\tau} = 291.4 \pm 3.0 fs and find that the ratio of the coupling constant for tau decay relative to that for muon decay is 0.990 \pm 0.009, compatible with lepton universality.

research product

Measurement of $\Delta^{++}$(1232) production in hadronic Z decays

A measurement of the \Delta^{++}(1232) inclusive production in hadronic decays of the Z at LEP is presented, based on 1.3 million hadronic events collected~ by the DELPHI~ detector in the 1994 LEP running~ period. The DELPHI ring imaging Cherenkov counters are used for identifying hadrons. The average \Delta^{++}(1232) multiplicity per hadronic event is 0.079 \pm 0.015 which is more than a factor of two below the JETSET, HERWIG and UCLA model predictions. It agrees with a recently proposed universal mass dependence of particle production rates in e^{+}e^- annihilations.

research product

Energy dependence of the differences between the quark and gluon jet fragmentation

Three jet events arising from decays of the Z beson, collected by the DELPHI detector, were used to measure differences in quark and gluon fragmentation. Gluon jets were anti-tagged by identifying b quark jets. Unbiased quark jets came from events with two jets plus one photon. Quark and gluon jet properties in different energy ranges were compared for the first time within the same detector. Quark and gluon jets of nearly the same energy in symmetric three jet event topologies were also compared. Using three independent methods, the average value of the ratio of the mean charged multiplicities of gluon and quark jets is [ r ] = 1.241 +/- 0.015 (stat.) +/- 0.025 (syst.). Gluon jets are broa…

research product