0000000000378759

AUTHOR

Audrey Letourneau

showing 2 related works from this author

Precision Muon Reconstruction in Double Chooz

2014

We describe a muon track reconstruction algorithm for the reactor anti-neutrino experiment Double Chooz. The Double Chooz detector consists of two optically isolated volumes of liquid scintillator viewed by PMTs, and an Outer Veto above these made of crossed scintillator strips. Muons are reconstructed by their Outer Veto hit positions along with timing information from the other two detector volumes. All muons are fit under the hypothesis that they are through-going and ultrarelativistic. If the energy depositions suggest that the muon may have stopped, the reconstruction fits also for this hypothesis and chooses between the two via the relative goodness-of-fit. In the ideal case of a thro…

Nuclear and High Energy PhysicsParticle physicsPhysics - Instrumentation and DetectorsPhysics::Instrumentation and DetectorsFOS: Physical sciencesSTRIPSDouble Chooz; Muon reconstruction; Neutrino detector[PHYS.NEXP]Physics [physics]/Nuclear Experiment [nucl-ex]CHOOZScintillatorHigh Energy Physics - Experimentlaw.inventionNONuclear physicsNeutrino detectorHigh Energy Physics - Experiment (hep-ex)law[PHYS.HEXP]Physics [physics]/High Energy Physics - Experiment [hep-ex][PHYS.PHYS.PHYS-INS-DET]Physics [physics]/Physics [physics]/Instrumentation and Detectors [physics.ins-det]InstrumentationImage resolutionPhysicsMuonDetectorReconstruction algorithmInstrumentation and Detectors (physics.ins-det)Double ChoozNeutrino detectorPhysics::Accelerator PhysicsHigh Energy Physics::ExperimentMuon reconstruction
researchProduct

Muon capture on light isotopes measured with the Double Chooz detector

2016

Using the Double Chooz detector, designed to measure the neutrino mixing angle $\theta_{13}$, the products of $\mu^-$ capture on $^{12}$C, $^{13}$C, $^{14}$N and $^{16}$O have been measured. Over a period of 489.5 days, $2.3\times10^6$ stopping cosmic $\mu^-$ have been collected, of which $1.8\times10^5$ captured on carbon, nitrogen, or oxygen nuclei in the inner detector scintillator or acrylic vessels. The resulting isotopes were tagged using prompt neutron emission (when applicable), the subsequent beta decays, and, in some cases, $\beta$-delayed neutrons. The most precise measurement of the rate of $^{12}\mathrm C(\mu^-,\nu)^{12}\mathrm B$ to date is reported: $6.57^{+0.11}_{-0.21}\time…

PhysicsSemileptonic decayParticle physicseducation.field_of_studyMuon010308 nuclear & particles physicsPopulationneutrino physic01 natural sciencesMuon captureNuclear physics13. Climate action0103 physical sciencesHigh Energy Physics::ExperimentNeutronProduction (computer science)Neutrino010306 general physicsGround stateeducation
researchProduct