Multicenter clinical trial of ultrasonic circular cyclo coagulation in patients with open-angle glaucoma: One year results
International audience; Purpose: To evaluate the efficacy and safety of the Ultrasonic Circular Cyclo Coagulation (UC3) procedure with one year of follow-up. Methods: Prospective non comparative interventional clinical study performed in 9 French glaucoma centers. Fifty-two eyes of 52 patients with open-angle glaucoma, intraocular pressure (IOP) > 21 mmHg, an average of 1.7 failed previous surgeries and an average of 3.7 hypotensive medications were insonified with a therapy probe comprising 6 piezoelectric transducers. The 6 transducers were activated, 24 patients (group 1) were treated with a 4 seconds exposure time for each shot and 28 patients (group 2) with a 6 seconds exposure time. C…