0000000000383248
AUTHOR
Ignacio Pla-gil
Una rara tumoración benigna en el dorso nasal
Primeras experiencias con el dispositivo osteointegrado Ponto™ SuperPower
Resumen Los dispositivos auditivos osteointegrados (DAO) Power y SuperPower presentan indicaciones para umbrales en via osea de 55 y 65 dB, respectivamente. Realizamos un estudio observacional prospectivo de una serie de 6 casos con hipoacusia mixta en los que se realizo implantacion del DAO Ponto™ SuperPower. Se realizaron previo a la implantacion y 6 meses tras la adaptacion valoraciones tonales y verbales sin y con ruido de fondo (HINTS). Todos los participantes mostraron mejoria en los resultados tonales y verbales, variando segun el grado de hipoacusia contralateral. Cabe destacar los resultados verbales con ruido de fondo donde la mayoria de los pacientes obtuvieron una relacion senal…
Audiologic and Subjective Evaluation of Baha ® Attract Device
We included 9 patients implanted with Baha® Attract. All our patients were evaluated by free field tonal audiometry, free field verbal audiometry and free field verbal audiometry with background noise, all the tests were performed with and without the device. To evaluate the subjective component of the implantation, we used the Glasgow Benefit Inventory (GBI) and Abbreviated Profile of Hearing Aid Benefit (APHAB). The auditive assessment with the device showed average auditive thresholds of 35.8dB with improvements of 25.8dB over the previous situation. Speech reception thresholds were 37dB with Baha® Attract, showing improvements of 23dB. Maximum discrimination thresholds showed an average…
Papiloma invertido de oído medio y hueso temporal
Análisis de la potencia de salida y del rendimiento auditivo de los dispositivos auditivos osteointegrados
Resumen Antecedentes y objetivos Los dispositivos auditivos osteointegrados utilizan la transmision del sonido por via osea para producir una mejoria auditiva. Los mecanismos y factores que intervienen en esta transmision han sido ampliamente estudiados, sin embargo, existen otros aspectos que no conocemos, por ejemplo, la influencia que tiene la potencia de salida del procesador. El objetivo principal de este estudio fue conocer si existe alguna relacion entre la potencia que emiten estos dispositivos y la mejoria auditiva que producen. Materiales y metodos Hemos realizado un estudio en 44 pacientes portadores de un Baha® 5 percutaneo. De cada paciente se obtuvieron los umbrales de via aer…
A Rare Benign Tumour on the Dorsum Nasi
First Experiences With the Ponto⢢ SuperPower Osseointegrated Device
Osseointegrated hearing devices Power and SuperPower present indications for bone thresholds of 55 and 65 dB respectively. We conducted a prospective observational study of a series of six cases with mixed hearing loss for whom implantation of the DAO Ponto™ Super-Power was performed. Tonal and verbal evaluations without and with background noise (HINTS) were performed prior to implantation and six months after adaptation. All the participants showed improvement in tonal and verbal results, varying according to the degree of contralateral hearing loss. The verbal results with background noise were noteworthy, where most of the patients obtained a signal-to-noise ratio between 2 and 4 dB. Th…
Inverted papilloma of middle ear and temporal bone.
Epidermoid Septal Carcinoma, A Rare and Singular Tumor: Case Report and Review
Aim: To describe our casuistic and the way we manage these tumors with their differential behavior. Background: Septal epidermoid carcinoma is a rare tumor that accounts for only 9% of tumors of the nasal fossa. This tumor presents histological, clinical, and prognostic characteristics that differentiate it from other nasal cavity tumors, mainly its anterior location that leads to an early diagnosis in incipient stages. Case description: We present a series of six patients diagnosed with nasal squamous cell carcinoma as well as the clinic referred by the patients to the diagnosis, the associated risk factors, and their clinical and therapeutic approach. Conclusion: The majority of cases (4/…
Valoración audiológica y subjetiva del dispositivo Baha ® Attract
Resumen Se incluyeron en el estudio 9 pacientes implantados con el dispositivo Baha® Attract. A todos los pacientes se les realizo, con y sin el dispositivo, una audiometria tonal en campo libre, una audiometria verbal en campo libre, y una audiometria verbal con ruido de fondo, asi como la aplicacion de los cuestionarios Glasgow Benefit Inventory (GBI) y Abbreviated Profile of Hearing Aid Benefit (APHAB). Las valoraciones audiologicas con el dispositivo mostraron unos umbrales auditivos promedios de 35,8 dB, con ganancias medias de 25,8 dB. El umbral de recepcion verbal promedio con el dispositivo se situo en 37 dB, mostrando una ganancia de 23 dB. Los resultados promedio del umbral de dis…