M. Puderbach
3 He-MRI-based vs. conventional determination of lung volumes in patients after unilateral lung transplantation: a new approach to regional spirometry
Background: To use 3Helium (3He)-MRI in patients with unilateral lung grafts to assess the contributions of graft and native lung to total ventilated lung volume, and second to compare conventional measurements of intrapulmonary gas volume (spirometry, body plethysmography) with image-based volumetry of ventilated lung parenchyma visualized by hyperpolarized 3He-MRI. Methods: With Ethics Committee approval, five patients with single lung transplantation (SLTX) for idiopathic pulmonary fibrosis (IPF) underwent both conventional pulmonary function testing (PFT) and 3He-MRI of the lung. Intrapulmonary gas volume (GV) during the inspiratory breathhold for 3He-MRI was calculated from measured fu…
SPLIT-LUNG VOLUMETRY IN PATIENTS AFTER SINGLE-LUNG TRANSPLANTATION USING 3HELIUM-MRI
MRI in lung transplant recipients using hyperpolarized 3He: comparison with CT.
PURPOSE To elucidate the ability of 3He-MRI to detect ventilation defects in lung transplant recipients, 3He-MRI was compared to CT for concordance. MATERIALS AND METHODS We examined 14 lung recipients using 3He-MRI on a 1.5 T MR scanner. CT served as a reference method. Up to four representative ventilation defects were defined for each lung on 3He-MRI and compared to corresponding areas on CT. RESULTS Altogether, 59 representative ventilation defects were defined on 3He-MRI. Plausible CT correlates were found for 29 ventilation defects; less plausible CT correlates were found for eight defects. In 22 defects (37%) no corresponding CT changes were detected. CT demonstrated correlates for v…
3He MRI in healthy volunteers: preliminary correlation with smoking history and lung volumes
MRI with hyperpolarized helium-3 (3He) provides high-resolution imaging of ventilated airspaces. The first aim of this 3He-study was to compare observations of localized signal defects in healthy smokers and non-smokers. A second aim was to describe relationships between parameters of lung function, volume of inspired 3He and signal-to-noise ratio. With Ethics Committee approval and informed consent, 12 healthy volunteers (seven smokers and five non-smokers) were studied. Imaging was performed in a 1.5 T scanner using a two-dimensional FLASH sequence at 30V transmitter amplitude (TR/TE/α = 11 ms/4.2 ms/<10°). Known amounts of 3He were inhaled from a microprocessor-controlled delivery device…