0000000000388032

AUTHOR

Emilio Cuevas

Chemical composition and complex refractive index of Saharan Mineral Dust at Izaña, Tenerife (Spain) derived by electron microscopy

Abstract Samples from two strong homogeneous dust plumes from the Saharan desert reaching Izana (Tenerife, Spain) in July and August 2005 were taken with a miniature impactor system and filter samplers. Size, aspect ratio and chemical composition of more than 22,000 individual particles were studied by scanning electron microscopy. The mineralogical phase composition of about 200 particles was investigated by transmission electron microscopy. In addition, the aerosol size distribution was measured with an optical particle spectrometer. In all samples, the aerosol was dominated by mineral dust with an average composition (by volume) of 64% silicates, 6% quartz, 5% calcium-rich particles, 14%…

research product

UV Index Experimental Values During the Years 2000 and 2001 from the Spanish Broadband UV-B Radiometric Network¶

An analysis is made of experimental ultraviolet erythemal solar radiation data measured during the years 2000 and 2001 by the Spanish UV-B radiation evaluation and prediction network. This network consists of 16 Robertson-Berger type pyranometers for evaluating solar erythemal radiation and five Brewer spectroradiometers for evaluating the stratospheric ozone. On the basis of these data the Ultraviolet Index (UVI) was evaluated for the measuring stations that are located either in coastal regions or in the more densely populated regions inland on the Iberian Peninsula. It has been checked that in most cases the maximum irradiance values corresponded to solar noon, although there were except…

research product

Results from the Fourth WMO Filter Radiometer Comparison for aerosol optical depth measurements

Abstract. This study presents the results of the Fourth Filter Radiometer Comparison that was held in Davos, Switzerland, between 28 September and 16 October 2015. Thirty filter radiometers and spectroradiometers from 12 countries participated including reference instruments from global aerosol networks. The absolute differences of all instruments compared to the reference have been based on the World Meteorological Organization (WMO) criterion defined as follows: 95% of the measured data has to be within 0.005 ± 0.001∕m (where m is the air mass). At least 24 out of 29 instruments achieved this goal at both 500 and 865 nm, while 12 out of 17 and 13 out of 21 achieved this at 368 and 412 nm,…

research product