Approach to a water safety plan for recreational waters: disinfection of a drainage pumping station as an unconventional point source of fecal contamination
Abstract In the context of the management of bathing water quality, the intermittent contamination of rainwater drainage pumps (unconventional point sources) could be controlled by peracetic acid disinfection. Thus, a field experimental study was carried out to set up a water safety plan, determining the monitoring parameters and the critical limit for corrective actions. With a 0.5 mg/l dosage, the average logarithmic microbial reduction was 0.50 ± 0.48 for Escherichia coli (EC) and 0.43 ± 0.54 for intestinal enterococci. Among the chemical and physical parameters that could be monitored in real time, the oxidation–reduction potential was the only one able to predict the microbial concentr…