0000000000389847

AUTHOR

Anton Moritz

showing 5 related works from this author

Anatomic and flow dynamic considerations for safe right axillary artery cannulation.

2013

Objectives Neuroprotection is of paramount interest in cardiac surgery. Right axillary artery cannulation is well established in aortic surgery because it significantly improves survival and outcome, but malperfusion of the right brain after direct cannulation has been reported. Anatomically, 4 vessel segments are potentially amenable for cannulation of the subclavian and axillary arteries. Clinical studies vary widely in dissection sites and cannulation techniques. We investigated critical flow dynamics in the right brain caused by arterial inflow after direct cannulation and specified cannulation positions that provide optimal cerebral perfusion. Methods Distances from the lateral margin …

Pulmonary and Respiratory MedicineMalemedicine.medical_specialtyVertebral arterySubclavian ArteryHemodynamicsDissection (medical)Axillary arterymedicine.arteryCatheterization PeripheralmedicineCadaverHumansComputer SimulationCerebral perfusion pressureSubclavian arteryVertebral Arterybusiness.industryModels Cardiovascularmedicine.diseaseCannulaCardiac surgerySurgeryRegional Blood FlowCerebrovascular CirculationAxillary ArterySurgeryFemaleRadiologyAnatomic LandmarksbusinessCardiology and Cardiovascular MedicineBlood Flow VelocityThe Journal of thoracic and cardiovascular surgery
researchProduct

Levosimendan protects human hepatocytes from ischemia-reperfusion injury.

2017

Background Ischemia-reperfusion injury (IRI) is a major challenge in liver transplantation. The mitochondrial pathway plays a pivotal role in hepatic IRI. Levosimendan, a calcium channel sensitizer, was shown to attenuate apoptosis after IRI in animal livers. The aim of this study was to investigate the effect of levosimendan on apoptosis in human hepatocytes. Methods Primary human hepatocytes were either exposed to hypoxia or cultured under normoxic conditions. After the hypoxic phase, reoxygenation was implemented and cells were treated with different concentrations of levosimendan (10ng/ml, 100ng/ml, 1000ng/ml). The overall metabolic activity of the cells was measured using 3-(4,5-dimeth…

0301 basic medicineNecrosisCritical Care and Emergency Medicinelcsh:MedicineApoptosis030204 cardiovascular system & hematologyBiochemistry0302 clinical medicineAnimal CellsMedicine and Health SciencesEnzyme assaysColorimetric assayslcsh:ScienceBioassays and physiological analysisCells CulturedEnergy-Producing Organellesbcl-2-Associated X ProteinMultidisciplinaryMTT assaybiologyCell DeathMitochondriaPyridazinesLiverCell ProcessesReperfusion Injurymedicine.symptomCellular TypesAnatomyCellular Structures and Organellesmedicine.drugResearch Articlemedicine.medical_specialtyCell PhysiologyIschemiaCardiologySurgical and Invasive Medical ProceduresBioenergetics03 medical and health sciencesDigestive System ProceduresBcl-2-associated X proteinInternal medicinemedicineHumansMTT assayddc:610SimendanHeart FailureTransplantationbusiness.industrylcsh:RHydrazonesBiology and Life SciencesLevosimendanCell BiologyOrgan TransplantationHypoxia (medical)medicine.diseaseLiver TransplantationCell MetabolismResearch and analysis methods030104 developmental biologyEndocrinologyApoptosisReperfusionBiochemical analysisbiology.proteinHepatocyteslcsh:QbusinessReperfusion injuryPloS one
researchProduct

Assessment of the distal anastomosis of coronary artery bypass grafts with a 2D T2-weighted turbo spin echo sequence and correlation to conventional …

2005

Abstract Objective The aim of the study was to evaluate the patensies of the distal anastomoses of coronary artery bypass grafts and to detect graft stenoses and occlusions with a magnetic resonance (MR) spin echo sequence. Patients and methods One hundred and eighty-five patients with 481 distal anastomoses were examined with a 1.5 T MR scanner and coronary angiography. A 2-dimensional T2-weigthed breath-hold half-Fourier acquisition single-shot turbo spin echo sequence (Haste) was performed. All images were evaluated independently by a radiologist and cardiologist and compared to the conventional coronary angiography. The observers were blinded to the coronary angiography findings, but in…

AdultMaleCoronary angiographymedicine.medical_specialtyAnastomosisCoronary AngiographySensitivity and SpecificitymedicineHumansSaphenous VeinCoronary Artery BypassVascular PatencyAgedDistal anastomosisSequence (medicine)Aged 80 and overObserver Variationmedicine.diagnostic_testEcho-Planar Imagingbusiness.industryAnastomosis SurgicalCoronary StenosisMagnetic resonance imagingMiddle AgedImage EnhancementTreatment Outcomemedicine.anatomical_structureCirculatory systemSpin echoPatient ComplianceFemaleRadiologyArtifactsCardiology and Cardiovascular MedicinebusinessArteryInternational Journal of Cardiology
researchProduct

External stenting with a new polyester mesh reduces neointimal hyperplasia of vein grafts in a sheep model.

2007

Objective External stents placed around vein grafts have demonstrated effectiveness in reducing neointimal hyperplasia by preventing distension of the thin-walled vein grafts when exposed to arterial pressure. However, the ideal stent material has yet to be defined. The following study investigates the short- and long-term effects of an innovative polyester mesh stent designed with optimized adaptation of circumferential compliance. Methods Following in vitro definition of the ideal macro-porous polyester stent material, a total of 12 sheep underwent implantation of bilateral carotid artery vein graft bypasses. In six sheep, the short-term outcome (four weeks of implantation) was investigat…

Carotid Artery Diseasesmedicine.medical_specialtyCarotid Artery CommonCarotid arteriesmedicine.medical_treatmentPolyesters030232 urology & nephrologyBiomedical EngineeringMedicine (miscellaneous)BioengineeringVein graft030204 cardiovascular system & hematologyDistensionBiomaterials03 medical and health sciencesBlood Vessel Prosthesis Implantation0302 clinical medicineMedicineAnimalsSaphenous VeinNeointimal hyperplasiaPolyester meshHyperplasiaSheepbusiness.industryGraft Occlusion VascularStentGeneral MedicineSurgical Meshequipment and suppliesmedicine.diseaseSurgeryCompliance (physiology)Disease Models Animalsurgical procedures operativeSurgical meshStentsbusinessTunica IntimaDilatation PathologicThe International journal of artificial organs
researchProduct

Acute Aortic Dissection Type A : Age-related Management and Outcomes Reported in the German Registry for Acute Aortic Dissection Type A (GERAADA) of …

2013

To determine the association between age and clinical presentation, management and surgical outcomes in a large contemporary, prospective cohort of patients with acute aortic dissection type A (AADA).AADA is one of the most life-threatening cardiovascular diseases, and delayed surgery or overly conservative management can result in sudden death.The perioperative and intraoperative conditions of 2137 patients prospectively reported to the multicenter German Registry for Acute Aortic Dissection Type A were analyzed.Of all patients with AADA, 640 (30%) were 70 years or older and 160 patients (7%) were younger than 40 years. The probability of aortic dissection extension to the supra-aortic ves…

AdultMalemedicine.medical_specialtyMedizinlaw.inventionYoung AdultAortic aneurysmSex FactorsAneurysmRandomized controlled triallawGermanymedicineHumansProspective StudiesRegistriesYoung adultProspective cohort studyAgedAortic dissectionAortic Aneurysm Thoracicbusiness.industryfungiAge FactorsMiddle AgedPrognosismedicine.diseaseSurgerySurvival RateAortic DissectionCardiothoracic surgeryAustriaFemaleSurgeryMorbiditybusinessVascular Surgical ProceduresSwitzerlandAortic Aneurysm AbdominalFollow-Up StudiesAbdominal surgery
researchProduct