0000000000392515

AUTHOR

N. Schmidt

Clinical Anatomy and information technology.

research product

PHP39 Explaning Differences in EU5 Market Penetration Levels and Rates of Biosimilars: The Case of Epoetine, Granulocyte-Colony Stimulating Factor, and Growth Hormones

research product

SARS-CoV-2 vaccination modelling for safe surgery to save lives: data from an international prospective cohort study

Abstract Background Preoperative SARS-CoV-2 vaccination could support safer elective surgery. Vaccine numbers are limited so this study aimed to inform their prioritization by modelling. Methods The primary outcome was the number needed to vaccinate (NNV) to prevent one COVID-19-related death in 1 year. NNVs were based on postoperative SARS-CoV-2 rates and mortality in an international cohort study (surgical patients), and community SARS-CoV-2 incidence and case fatality data (general population). NNV estimates were stratified by age (18–49, 50–69, 70 or more years) and type of surgery. Best- and worst-case scenarios were used to describe uncertainty. Results NNVs were more favourable in su…

research product

Search for a common baryon source in high-multiplicity pp collisions at the LHC

Physics letters / B B811, 135849 (2020). doi:10.1016/j.physletb.2020.135849

research product

First laser cooling of relativistic ions in a storage ring

The first successful laser cooling of ions at relativistic energies was observed at the Heidelberg TSR storage ring. A $^{7}\mathrm{Li}^{+}$-ion beam of 13.3 MeV was oberlapped with resonant copropagating and counterpropagating laser beams. The metastable ions were cooled from 260 K to a longitudinal temperature of below 3 K and decelerated by several keV. The longitudinal velocity distribution was determined by a fluorescence method. After laser cooling a strongly enhanced narrow peak appeared in the Schottky noise spectrum in addition to the uncooled ion distribution.

research product

First experiments with the heidelberg test storage ring TSR

Abstract The Heidelberg heavy ion test storage ring TSR started operation in May 1988. The lifetimes of the ion beams observed in the first experiments can be explained by interactions with the residual gas. Multiple Coulomb scattering, single Coulomb scattering, electron capture and electron stripping are the relevant processes. Electron cooling of ions as heavy as O 8+ has been observed for the first time. With increasing particle number, the longitudinal Schottky noise spectrum becomes dominated by collective waves for cooled beams, allowing a determination of velocities of sound. After correcting for these coherent distortions fo the Schottky spectrum, the longitudinal beam temperature …

research product