0000000000396094

AUTHOR

E. Simon

Abstract of the 68th Meeting (Spring Meeting) 6–9 March 1990, Heidelberg

research product

Republication de: recommandations formalisées d'experts. Prise en charge de la patiente avec une pré-éclampsie sévère–RFE communes Société française d'anesthésie-réanimation (SFAR)–Collège national des gynécologues et obstétriciens français (CGNOF)

International audience; Objective: To provide national guidelines for the management of women with severe preeclampsia. Design: A consensus committee of 26 experts was formed. A formal conflict of interest (COI) policy was developed at the onset of the process and enforced throughout. The entire guidelines process was conducted independently of any industrial funding. The authors were advised to follow the principles of the Grading of Recommendations Assessment, Development and Evaluation (GRADE®) system to guide assessment of quality of evidence. The potential drawbacks of making strong recommendations in the presence of low-quality evidence were emphasized. Methods: The last SFAR and CNGO…

research product

Interpretation of the Anomalous NaI Events

Anomalous events, with scintillation decay times shorter than nuclear recoils, have been observed by the UKDMC and Saclay NaI experiments. By using the event categories observed in the EDELWEISS experiment, we propose to interpret the anomalous NaI events as surface nuclear recoils accompanied with a small energy loss of an escaping alpha particle. The discrimination performances of the NaI experiments which have not taken into account these events in their analysis, notably for axial WIMP interactions, must then be reevaluated.

research product

Status of the EDELWEISS experiment

The Edelweiss Dark Matter Experiment is installed in the Modane Underground Laboratory since 1994. In 1997 the first detector of a 70 g heat and ionization Ge low-temperature detector built by the collaboration showed its discrimination capabilities. During the last two years the installation was upgraded, and a new generation of 70 g Ge detectors is operational. The detector environment is drastically controlled to avoid radioactive contamination. A test run with two new 70 g detectors shows a reduction by a factor of ten in the background level before 7-ray rejection which is now around 2 events/kg/keV/day. Three 320 g Ge cryogenic detectors have been constructed and are now being tested …

research product

Background discrimination capabilities of a heat and ionization germanium cryogenic detector

The discrimination capabilities of a 70 g heat and ionization Ge bolometer are studied. This first prototype has been used by the EDELWEISS Dark Matter experiment, installed in the Laboratoire Souterrain de Modane, for direct detection of WIMPs. Gamma and neutron calibrations demonstrate that this type of detector is able to reject more than 99.6% of the background while retaining 95% of the signal, provided that the background events distribution is not biased towards the surface of the Ge crystal. However, the 1.17 kg.day of data taken in a relatively important radioactive environment show an extra population slightly overlapping the signal. This background is likely due to interactions o…

research product