Determination of Third-Generation Synthetic Cannabinoids in Oral Fluids.
Abstract A procedure has been developed for the determination of third-generation synthetic cannabinoids in oral fluid samples by using a semi-automated microextraction by packed sorbent (MEPS) procedure and gas chromatography–mass spectrometry (GC–MS) determination. Five synthetic cannabinoids were employed as model compounds 5F-ADB, MMB-CHMICA, THJ-2201, CUMYL-4CN-BINACA and MDMB-CHMCZCA. The most adequate operative conditions for MEPS were evaluated giving quantitative recoveries, from 89 to 124%, in synthetic and field saliva samples spiked with 125 and 250 μg/L of the studied cannabinoids, with the exception of MDMB-CHMCZCA in field saliva samples that provided slightly lower recoverie…