0000000000407510

AUTHOR

Jens Decking

showing 10 related works from this author

The internal calcar septum and its contact with the virtual stem in THR: a computer tomographic evaluation.

2003

The internal calcar septum is a ridge of cortical bone protruding from the inner cortical wall of the proximal femur into the medullary canal. It extends from the lesser trochanter into the femoral neck and narrows the femoral cavity in its dorsal third. This region is essential for THR stability, but the degree of contact between the septum and standard THR implants has never been studied. We obtained CT scans of 50 arthrotic hip joints from patients requiring THR. Virtual stems (50 straight/wedge-shaped and 50 anatomic stems) were placed in CT images of the femora using a PC-based preoperative planning unit. The dimensions of the septum, degree and location of contact between the septum a…

Adultmedicine.medical_specialtyCalcarMedullary cavitybusiness.industryArthroplasty Replacement HipAnatomyRoboticsMiddle Agedmedicine.anatomical_structureLesser TrochanterOrthopedic surgerymedicineImage Processing Computer-AssistedHumansOrthopedics and Sports MedicineSurgeryCortical boneFemurImplantFemurHip ProsthesisbusinessTomography X-Ray ComputedFemoral neckActa orthopaedica Scandinavica
researchProduct

The impact of Syme amputation in surgical treatment of patients with diabetic foot syndrome and Charcot-neuro-osteoarthropathy

2002

Charcot-neuro-osteoarthropathy with its severe destruction of bones remains a challenge for physicians and surgeons. The aim of the study was to characterise a patient population treated in a specialised foot care centre who underwent surgical treatment for their diabetic foot syndrome. Special attention was paid to patients who suffered from Charcot-neuro-osteoarthropathy and the impact of Syme amputation if amputation of the foot was inevitable. A total of 121 patients with diabetic foot syndrome and ulcerations underwent an interdisciplinary strategy for diagnostic and therapeutic procedures including MRI and surgical interventions. If peripheral arterial vessel disease was present, reva…

AdultMalemedicine.medical_specialtymedicine.medical_treatmentPerforation (oil well)PopulationAmputation SurgicalBlood Vessel Prosthesis ImplantationSpinal osteoarthropathymedicine.arterymedicineHumansOrthopedics and Sports MedicineeducationAgedAged 80 and overeducation.field_of_studybusiness.industryOsteomyelitisGeneral MedicineMiddle Agedmedicine.diseaseDiabetic footDiabetic FootSurgeryPosterior tibial arteryTreatment OutcomeAmputationOrthopedic surgeryFemaleSurgeryArthropathy NeurogenicbusinessArchives of Orthopaedic and Trauma Surgery
researchProduct

Preserving the abductor mechanism in robotic THR: the influence of stem design and cutterpath.

2004

The tip of the greater trochanter is the attachment site for the abductor muscles of the hip joint. Its preservation in robotic and conventional THR is important for normal gait. The effect of different stem designs and robotic cutterpaths on the preservation of the trochanter tip is examined.One anatomical stem, one straight stem, and one stem specifically designed for robotic THR were implanted virtually in CT scans of osteoarthrotic hip joints using the Torch preoperative planning unit (URS-ortho). In transverse sections of the trochanter tip, dimensions of the trochanter area removed by the milling tool were recorded for each stem design and different cutterpaths (3-axis versus 5-axis m…

MaleGreater trochanterMaterials scienceAttachment siteArthroplasty Replacement HipUser-Computer InterfaceProsthesis FittingOsteoarthritismedicineHumansFemurMuscle SkeletalGaitPreoperative planningTrochantertechnology industry and agricultureStraight stemAnatomyRoboticsComputer Science ApplicationsMechanism (engineering)Normal gaitmedicine.anatomical_structureSurgery Computer-AssistedSurgeryMuscles of the hipFemaleHip JointFamily PracticeTomography X-Ray ComputedBiomedical engineeringComputer aided surgery : official journal of the International Society for Computer Aided Surgery
researchProduct

Robotic total knee arthroplastyThe accuracy of CT-based component placement

2004

Accurate alignment of the components in total knee arthroplasty is important. By use of postoperative CT controls, we studied the ability of a robotic effector to accurately place and align total knee arthroplasty (TKA) components according to a purely CT-based preoperative plan.Robotic TKA was performed in 13 patients (6 men) with primary gonarthrosis. Locator screws were placed into femur and tibia under spinal anesthesia. A CT-scan including the femoral head, knee and ankle was performed. In the preoperative planning software, virtual components were positioned into the CT volume. In a second operation, the robot milled femur and tibia with a high-speed milling tool according to the preo…

Legmedicine.medical_specialtybusiness.industryArthritismedicine.medical_treatmentmedia_common.quotation_subjectTotal knee arthroplastyRoboticsRoboticsProsthesisSurgeryPreoperative CaremedicineHumansOrthopedics and Sports MedicineSurgeryAptitudePostoperative PeriodArtificial intelligenceArthroplasty Replacement KneeTomography X-Ray Computedbusinesshuman activitiesComponent placementmedia_commonActa Orthopaedica Scandinavica
researchProduct

Arthrose und Osteoporose - Wirklich eine inverse Relation?

2005

Objective Increasing bone mineral density (BMD) has been found in several studies in patients with osteoarthritis (OA). Therefore, the simultaneous occurrence of osteoporosis (OP) and OA is denied by many clinicians. Because of our clinical impression, however, we suggest that we have to consider a common occurrence. In the present study we have examined the relationship between osteoathritis of the knee or the hip and osteoporosis. Method The BMD of the lumbar spine and the proximal femur of 117 OA patients (82 postmenopausal female patients aged 50-83 and 35 male patients aged 36-86 years) who subsequently required hip or knee replacements, but were otherwise healthy, was measured by dual…

musculoskeletal diseasesBone mineralmedicine.medical_specialtyBone densitybusiness.industryIncidence (epidemiology)OsteoporosisOsteoarthritismusculoskeletal systemLower riskmedicine.diseaseComorbidityOsteopeniaInternal medicinemedicinePhysical therapyOrthopedics and Sports MedicineSurgerybusinessZeitschrift für Orthopädie und ihre Grenzgebiete
researchProduct

Shock wave application for chronic plantar fasciitis in running athletes. A prospective, randomized, placebo-controlled trial.

2003

Background:Recent articles have reported success with repeated low-energy shock wave application for treatment of chronic plantar fasciitis in runners.Hypothesis:Shock wave treatment for chronic plantar fasciitis is safe and effective.Study Design:Prospective, randomized, placebo-controlled trial.Methods:Forty-five running athletes with intractable plantar heel pain for more than 12 months were enrolled; half were assigned to a treatment group that received three applications of 2100 impulses of low-energy shock waves, and half received sham treatment. Follow-up examinations were performed at 6 months and at 1 year by a blinded observer.Results:After 6 months, self-assessment of pain on fir…

AdultMalemedicine.medical_specialtyVisual analogue scalePlacebo-controlled studyPlantar fasciitisPhysical Therapy Sports Therapy and RehabilitationWalkingPlaceboRunning03 medical and health sciences0302 clinical medicineLithotripsyMedicineHumansOrthopedics and Sports MedicineSingle-Blind MethodProspective StudiesFasciitisMorningPain Measurement030222 orthopedicsbiologybusiness.industryAthletes030229 sport sciencesMiddle Agedbiology.organism_classificationmedicine.diseaseClinical trialTreatment OutcomeFasciitis PlantarPhysical therapyFemalemedicine.symptombusinessThe American journal of sports medicine
researchProduct

Repetitive low-energy shock wave treatment for chronic lateral epicondylitis in tennis players.

2004

Background There is conflicting evidence regarding extracorporeal shock wave treatment for chronic tennis elbow. Hypothesis Treatment with repetitive low-energy extracorporeal shock wave treatment is superior to repetitive placebo extracorporeal shock wave treatment. Methods Seventy-eight patients enrolled in a placebo-controlled trial. All patients were tennis players with recalcitrant MRIconfirmed tennis elbow of at least 12 months’ duration. Patients were randomly assigned to receive either active low-energy extracorporeal shock wave treatment given weekly for 3 weeks (treatment group 1) or an identical placebo extracorporeal shock wave treatment (sham group 2). Main outcome measure was …

AdultMalemedicine.medical_specialtyAdolescentPlacebo-controlled studyPhysical Therapy Sports Therapy and RehabilitationWristPlacebolaw.invention03 medical and health sciences0302 clinical medicineRandomized controlled triallawHand strengthLithotripsyTennis elbowmedicineHumansOrthopedics and Sports MedicineAgedPain Measurement030222 orthopedicsHand Strengthbusiness.industryEpicondylitisTennis Elbow030229 sport sciencesMiddle Agedmedicine.diseaseMagnetic Resonance ImagingSurgerymedicine.anatomical_structureTreatment OutcomeOrthopedic surgeryChronic DiseaseFemalebusinessThe American journal of sports medicine
researchProduct

Cementless total hip replacement with subtrochanteric femoral shortening for severe developmental dysplasia of the hip.

2003

Total joint replacement in patients suffering from developmental dysplasia of the hip poses specific technical difficulties due to insufficient bone stock at the site of the original and secondary acetabulum and a narrow, cranially displaced proximal femur. Twelve hips with severe congenital dislocation (4 Crowe type II, 5 type III, 3 type IV) were treated with cementless, porous structured total hip replacement. The cup was implanted at the anatomic height, a femoral segment was resected below the minor trochanter to reduce the femoral component in all cases. One femoral component was exchanged for a longer stem after 2 months due to insufficient fit and fill. After a mean follow-up of 5.1…

musculoskeletal diseasesAdultMalemedicine.medical_specialtymedicine.medical_treatmentArthroplasty Replacement HipOsteotomymedicineHumansOrthopedics and Sports MedicineFemurFemurHip Dislocation CongenitalReduction (orthopedic surgery)Trochanterbusiness.industryGeneral MedicineMiddle Agedmedicine.diseaseAcetabulumSurgeryRadiographyHarris Hip ScoreDysplasiaOrthopedic surgerySurgeryFemalebusinessArchives of orthopaedic and trauma surgery
researchProduct

The migration of femoral components after total hip replacement surgery: accuracy and precision of software-aided measurements.

2003

To assess the accuracy and precision of a software-aided system to measure migration of femoral components after total hip replacement (THR) on digitised radiographs.Subsidence and varus-valgus tilt of THR stems within the femur were measured on digitised anteroposterior pelvic radiographs. The measuring software (UMA, GEMED, Germany) relies on bony landmarks and comparability parameters of two consecutive radiographs. Its accuracy and precision were calculated by comparing it with the gold standard in migration measurements, radiostereometric analysis (RSA). Radiographs and corresponding RSA measurements were performed in 60 patients (38-69 years) following cementless THR surgery.The UMA s…

musculoskeletal diseasesAdultMaleAccuracy and precisionmedicine.medical_specialtymedicine.medical_treatmentRadiographyArthroplasty Replacement HipProsthesisRadiostereometric AnalysisForeign-Body MigrationmedicineImage Processing Computer-AssistedHumansRadiology Nuclear Medicine and imagingFemurFemurDigital radiographyAgedOrthodonticsReproducibilitybusiness.industryReproducibility of ResultsMiddle Agedmusculoskeletal systemSurgeryProsthesis FailureRadiographic Image EnhancementOrthopedic surgeryFemaleHip ProsthesisbusinessSkeletal radiology
researchProduct

The Artek cup for total hip replacement of dysplastic hip joints.

2003

One specific difficulty in total hip replacement for developmental dysplasia of the hip is a shallow acetabulum with a short anteroposterior diameter. In a prospective cohort study we investigated the short-term results of the Artek cup, designed with a shallow outline and a height-reduced metal inlay for a large size 38 mm metal head, in a group of female patients with mild dysplasia of the hip.Fourteen consecutive patients with 17 dysplastic hip joints were included in the study. Their average age was 42 years. Fourteen hips had dysplasia Crowe grade I; 3 hips had dysplasia Crowe grade II. The femoral head centre was localized according to Pagnano in zone 1 in 3 cases, in zone 3 in 6 case…

Mild DysplasiaAdultReoperationmedicine.medical_specialtymedicine.medical_treatmentArthroplasty Replacement HipBone graftingProsthesis DesignFemoral headmedicineHumansOrthopedics and Sports MedicineHip Dislocation CongenitalOrthodonticsbusiness.industryGeneral MedicineMiddle Agedmedicine.diseaseAcetabulumArthroplastySurgeryRadiographymedicine.anatomical_structureTreatment OutcomeDysplasiaHarris Hip ScoreOrthopedic surgerySurgeryFemaleHip ProsthesisbusinessFollow-Up StudiesArchives of orthopaedic and trauma surgery
researchProduct