0000000000407599

AUTHOR

Vicente Fernández-sánchez

showing 7 related works from this author

Changes of the eye optics after iris constriction☆

2010

Purpose: To evaluate the possible change in the optics of the human eye after iris constriction. Methods: Ocular aberrations were measured under natural viewing conditions in 26 eyes. The measured eyes fixated on a dim target while the contralateral eye was either occluded (so the measured eye had a large pupil) or highly illuminated (so the measured eye had a small pupil). The measured eyes fixated to a dim target placed 0.5 D beyond the subject’s far point. Zernike values obtained in both situations were compared within the same pupil diameter corresponding to the one obtained under the high illumination condition. Results: Significant variation in some aberration coefficients were found …

genetic structuresComputer scienceIrisAberraciones ocularesOcular aberrationsConstrictionOpticslcsh:OphthalmologyAberración esféricamedicinelcsh:QC350-467Spherical aberrationÓptica del ojoIris (anatomy)skin and connective tissue diseasesurogenital systembusiness.industryeye diseasesSpherical aberrationmedicine.anatomical_structurelcsh:RE1-994Eye opticsHuman eyeOriginal Articlesense organsbusinesslcsh:Optics. LightOptometry
researchProduct

Changes in the objective amplitude of accommodation with pupil size.

2014

PURPOSE We evaluate the effect of pupil size on objectively measured amplitude of accommodation (AA). METHODS Pupil diameter and wavefront aberrometry were obtained in 15 eyes when stimulus swept across the range of clear vision in steps of 0.5 diopters. Wavefront refraction techniques were used to compute objective AA as the maximum refractive change. Measurements were obtained monocularly under low and high ambient room lighting conditions with a fixed luminance of the fixation target. Amplitude of accommodation computations were performed taking into account just paraxial rays (paraxial AA) or including the effects of the change of spherical aberration during accommodation (minRMS AA). R…

MiosisAdultMaleCorneal Wavefront AberrationLightRefraction OcularLuminancePupilCorneaYoung AdultOpticsmedicineHumansDioptrePhysicsbusiness.industryAberrometryParaxial approximationAccommodation OcularPupilAmplitude of accommodationOphthalmologySpherical aberrationFemalemedicine.symptombusinessAccommodationOptometryOptometry and vision science : official publication of the American Academy of Optometry
researchProduct

Accommodation-related changes in monochromatic aberrations of the human eye as a function of age.

2008

PURPOSE. To investigate the relationship between accommodation and the optical aberrations of the whole human eye, as a function of age. METHODS. Sixty healthy subjects with spherical ametropia in the range 3 D, astigmatism less than 1 D, corrected visual acuity of 20/18 or better, and normal findings in an ophthalmic examination were enrolled. Subjects were divided into four groups, with age ranges of 19 to 29, 30 to 39, 40 to 49, and 50 to 60 years. Monochromatic optical aberrations and pupil size were measured with a Hartmann-Shack wavefront sensor under monocular viewing conditions, without pharmacological dilation or cycloplegia. Stimulus vergences were in the range of 0 to 5 D, with a…

MiosisAdultMaleAgingVisual acuitygenetic structuresPupilRetinaContrast SensitivityMedicineHumansMonocularbusiness.industryAccommodation OcularCycloplegiaPupilMiddle AgedRefractive Errorseye diseasesSpherical aberrationmedicine.anatomical_structureOptometryHuman eyeFemalesense organsmedicine.symptombusinessAccommodationInvestigative ophthalmologyvisual science
researchProduct

Effect of 3rd-order aberrations on human vision

2007

To investigate the effect of 3rd-order aberrations on human vision.Grupo de Ciencias de la Visión, University of Murcia, Murcia, Spain.The 3rd-order aberrations coma and trefoil were induced with purpose-designed soft contact lenses, 3 inducing coma (low [0.05 microm], medium [0.13 microm], high [1.03 microm]) and 3 inducing trefoil (low [0.07 microm], medium [0.17 microm], high [0.96 microm]). Monocular high-contrast (HCVA) and low-contrast (LCVA) visual acuities and contrast sensitivity were measured in 11 subjects wearing contact lenses with a 5.0 mm artificial pupil.The reduction in HCVA and LCVA was statistically significant only for the highest coma and trefoil values (P.0001). For co…

AdultMalemedicine.medical_specialtygenetic structuresmedia_common.quotation_subjectmedicine.medical_treatmentVision DisordersVisual AcuityComa (optics)Models Biologicaldigestive systemContrast SensitivityOcular physiologyOpticsOphthalmologyRefractive surgeryHumansMedicineContrast (vision)TrefoilVision Ocularmedia_commonbusiness.industryContact Lenses HydrophilicRefractive ErrorsSensory SystemsInduced comaOphthalmologyFemaleSurgerybusinessJournal of Cataract and Refractive Surgery
researchProduct

Objective Amplitude of Accommodation Computed from Optical Quality Metrics Applied to Wavefront Outcomes

2009

Purpose: We studied the accuracy and precision of 32 objective wavefront methods for finding the amplitude of accommodation obtained in 180 eyes. Methods: Ocular accommodation was stimulated with 0.5 D steps in target vergence spanning the full range of accommodation for each subject. Subjective monocular amplitude of accommodation was measured using two clinical methods, using negative lenses and with a custom Badal optometer. Results: Both subjective methods gave similar results. Results obtained from the Badal optometer where used to test the accuracy of the objective methods. All objective methods showed lower amplitude of accommodation that the subjective ones by an amount that varied …

Accuracy and precisionamplitude of accommodationgenetic structuresComputer scienceAcousticssubjective methods050105 experimental psychology03 medical and health sciencesimage quality metricsobjective methods0302 clinical medicinelcsh:Ophthalmologymedicineamplitud de acomodaciónlcsh:QC350-4670501 psychology and cognitive sciencesmétodos subjetivosSimulationWavefrontmétricas de calidad de imagenmétodos objetivos05 social sciencespresbiciaPresbyopiamedicine.diseaseOptical qualityAmplitude of accommodationlcsh:RE1-994030221 ophthalmology & optometrypresbyopiaOriginal Articlelcsh:Optics. LightOptometryJournal of Optometry
researchProduct

Optical factors influencing the amplitude of accommodation

2017

AbstractThe purpose of this work was to find plausible predictors among optical parameters that may explain the inter-individual differences in subjective amplitude of accommodation not explained by age. An exploratory multivariable regression analysis was carried out retrospectively on a dataset with 180 eyes from 97 subjects (ages ranged from 20 to 58years). Subjective amplitudes of accommodation were recorded with the use of a custom-made Badal system. A commercial aberrometer was used to obtain each eye’s wavefront during the full range of accommodation. The plausible predictors under study were pupil diameter in the unaccommodated eye, its reduction with accommodation; fourth- and six-…

AdultMaleDepth of focusmedicine.medical_specialtyCorneal Wavefront Aberrationgenetic structuresZernike polynomialsAmplitude of accommodationAudiologyRefraction Ocular050105 experimental psychologyYoung Adult03 medical and health sciencessymbols.namesake0302 clinical medicineOpticsAberrometrymedicineHumans0501 psychology and cognitive sciencesSpherical aberrationRetrospective Studiesbusiness.industryAberrometry05 social sciencesAccommodation OcularPupilPresbyopiaPresbyopiaMiddle Agedmedicine.diseaseSubjective refractioneye diseasesAmplitude of accommodationSensory SystemsStatistical modelingSpherical aberrationOphthalmologyAmplitude030221 ophthalmology & optometrysymbolsRegression AnalysisFemalePsychologybusinessAccommodationVision Research
researchProduct

Comparison of partial coherence interferometry and ultrasound for anterior segment biometry.

2008

To assess the performance of a partial coherence interferometry (PCI)-based device for the determination of anterior segment biometry.Clinica Centrofama, Cartagena, Murcia, Spain.Central corneal thickness (CCT), anterior chamber depth (ACD), and lens thickness (LT) were measured with the ACMaster PCI anterior segment biometer and an Echoscan US-1800 ultrasound (US) biometer/pachymeter with and without cycloplegia. To determine the precision of the instruments, the same examiner took 30 consecutive CCT, ACD, and LT measurements in a single subject under the same conditions and with and without cycloplegia. The same measurements were performed in additional subjects.Twenty-one eyes (16 subjec…

AdultMalemedicine.medical_specialtyMydriaticsMaterials scienceBiometrygenetic structuresLightAnterior ChamberDiagnostic Techniques OphthalmologicalEyeCorneaLens thicknessOphthalmologyLens CrystallinemedicineHumansBody Weights and Measuresbusiness.industryUltrasoundReproducibility of ResultsCycloplegiaPupileye diseasesSensory SystemsSurgeryOphthalmologyInterferometrySoundPartial coherence interferometrySurgeryFemalesense organsmedicine.symptombusinessPartial coherenceJournal of cataract and refractive surgery
researchProduct