Anteil des frühen systolischen Flussanstiegs am antegrad fließenden Gesamtvolumen bei Phasenkontrast-Flussmessungen in Atemanhaltetechnik

2005

Purpose To evaluate the contribution of early systole for the assessment of antegrade aortic flow volume by breath-hold velocity-encoded magnetic resonance (MR) flow measurements. Materials and methods Expiratory breath-hold fast low-angle shot (FLASH) phase-contrast flow measurements (temporal resolution tRes 61 msec, shared phases) perpendicular to the proximal ascending aorta and short axis true fast imaging with steady-state precession (TrueFISP) cine MR ventriculometry (tRes 34.5 msec) were performed in ten healthy male volunteers on a 1.5 T MR system (Sonata, Siemens Medical Solutions). Antegrade aortic flow volume (AFV) and left ventricular stroke volume (LV-SV) were evaluated using …

medicine.medical_specialtyShort axisVentricular functionmedicine.diagnostic_testbusiness.industryPhase contrast microscopySignificant differenceMagnetic resonance imagingBlood flowlaw.inventionSurgeryVolume (thermodynamics)Flow (mathematics)Paired sampleslawmedicine.arteryAscending aortaLeft ventricular Stroke volumeMedicineRadiology Nuclear Medicine and imagingSystolebusinessNuclear medicineRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
researchProduct

Möglichkeiten der 16-Schicht-CT bei der linksventrikulären Funktionsbestimmung: Beurteilung zweier unterschiedlicher Software-Tools zur quantitativen…

2004

PURPOSE To determine global and regional left ventricular (LV) function from retrospectively gated multidetector row computed tomography (CT) by using two different semiautomated analysis tools and to correlate the results with those of magnetic resonance imaging (MRI). MATERIALS AND METHODS Nineteen patients (5 females, 14 males, mean age 69 years) underwent 16-slice spiral-CT (MS-CT) with standard technique without administration of beta-blockers for a decrease in the cardiac rate. Ten series of images were reconstructed at every 10 % of the RR-interval. With commercially available software capable of semiautomated contour detection, end-diastolic and end-systolic LV volumes (EDV and ESV)…

Contrast enhancementShort axisEjection fractionmedicine.diagnostic_testbusiness.industryLimits of agreementMagnetic resonance imagingStroke volumeStandard techniquemedicine.anatomical_structureVentricleMedicineRadiology Nuclear Medicine and imagingbusinessNuclear medicineRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren