0000000000420067
AUTHOR
R. P. Kunz
Anteil des frühen systolischen Flussanstiegs am antegrad fließenden Gesamtvolumen bei Phasenkontrast-Flussmessungen in Atemanhaltetechnik
Purpose To evaluate the contribution of early systole for the assessment of antegrade aortic flow volume by breath-hold velocity-encoded magnetic resonance (MR) flow measurements. Materials and methods Expiratory breath-hold fast low-angle shot (FLASH) phase-contrast flow measurements (temporal resolution tRes 61 msec, shared phases) perpendicular to the proximal ascending aorta and short axis true fast imaging with steady-state precession (TrueFISP) cine MR ventriculometry (tRes 34.5 msec) were performed in ten healthy male volunteers on a 1.5 T MR system (Sonata, Siemens Medical Solutions). Antegrade aortic flow volume (AFV) and left ventricular stroke volume (LV-SV) were evaluated using …
Koronare Bypassdiagnostik mit CT und MRT - eine Bestandsaufnahme
The limited lifetime and the correlation between graft occlusion and recurring symptoms underline the need for repeated imaging of coronary artery bypass grafts. CT and MRI allow for non-invasive imaging of coronary bypasses with high accuracies concerning the patency of these vessels. Multidetector CT seems to be the CT technique of choice, especially after the introduction of 16 slice CT scanners for morphologic assessment of coronary artery bypass grafts. Compared with MRI, CT is a robust technique for assessment of cardiac anastomoses, native coronary arteries, and for the detection of graft stenoses. MRI, however, is able to deliver functional information about the grafts and the recip…
Histopathological grading systems analysis of oral squamous cell carcinomas of young patients
Background: To analyze the clinicopathological profile of young patients (≤ 40 years) with oral SCC and correlate with a control group (≥ 50 years) by means of histopathological grading systems. Material and Methods: 14 young patients and 14 control patients were selected with similar clinical stage and tumor location. Demographic and clinical data were obtained from patient records and histological sections were evaluated according to four histopathological grading systems. Associations between categories of demographic and clinical data were performed through Chi-square test and Exact Fisher test. The survival analyzes were performed according to the Kaplan-Meier method. Results: The comp…
Anthrazyklin-induzierte Kardiotoxizität: MRT des Herzens bei Kindern und Jugendlichen mit malignen Erkrankungen
Purpose: Quantification of left and right ventricular function using MRI in young cancer patients treated with cardiotoxic anthracyclines. Materials and Methods: Twenty-eight patients (mean age 16.4 years) underwent cardiac MRI at 1.5 T. The study protocol consisted of morphologic T2-weighted images with fat suppression and cine steady-state free precession sequences (SSFP) for functional analysis. Seven patients were examined at the end of chemotherapy, two of them also repeatedly during therapy, and 21 patients following an average period of three years after finishing chemotherapy (range one month - 20 years) Results: The end-systolic volume index increased and the ejection fraction of t…
Systematische Analyse der Geometrie eines definierten Kontrastmittelbolus - Implikationen für die kontrastmittelverstärkte 3D-MR-Angiographie thorakaler Gefäße
Purpose: Little is known about the dispersion of a defined contrast bolus during its passage through the heart and pulmonary vasculature. The purpose of this study was to analyze factors influencing a defined contrast bolus for ce-MRA of thoracic vessels. Materials and Methods: For analysis of bolus geometry, an ECG-gated saturation-recovery Turbo-Flash sequence with a TI of 20 msec was used. It was acquired axially at the level of the pulmonary trunc, so that with one data acquisition a curve analysis was possible in the ascending and descending aorta, and in the pulmonary trunc. Twenty-nine patients received 3 ml of Gd-DTPA diluted with saline to a total of 20 ml. Contrast injection was d…
Quantification of pulmonary blood flow (PBF): validation of perfusion MRI and nonlinear contrast agent (CA) dose correction with H(2)15O positron emission tomography (PET).
Validation of quantification of pulmonary blood flow (PBF) with dynamic, contrast-enhanced MRI is still missing. A possible reason certainly lies in difficulties based on the nonlinear dependence of signal intensity (SI) from contrast agent (CA) concentration. Both aspects were addressed in this study. Nine healthy pigs were examined by first-pass perfusion MRI using gadolinium diethylenetriamine pentaacetic acid (Gd-DTPA) and HO positron emission tomography (PET) imaging. Calculations of hemodynamic parameters were based on a one-compartment model (MR) and a two-compartment model (PET). Simulations showed a significant error when assuming a linear relation between MR SI and CA dose in the …