0000000000420067

AUTHOR

R. P. Kunz

showing 6 related works from this author

Anteil des frühen systolischen Flussanstiegs am antegrad fließenden Gesamtvolumen bei Phasenkontrast-Flussmessungen in Atemanhaltetechnik

2005

Purpose To evaluate the contribution of early systole for the assessment of antegrade aortic flow volume by breath-hold velocity-encoded magnetic resonance (MR) flow measurements. Materials and methods Expiratory breath-hold fast low-angle shot (FLASH) phase-contrast flow measurements (temporal resolution tRes 61 msec, shared phases) perpendicular to the proximal ascending aorta and short axis true fast imaging with steady-state precession (TrueFISP) cine MR ventriculometry (tRes 34.5 msec) were performed in ten healthy male volunteers on a 1.5 T MR system (Sonata, Siemens Medical Solutions). Antegrade aortic flow volume (AFV) and left ventricular stroke volume (LV-SV) were evaluated using …

medicine.medical_specialtyShort axisVentricular functionmedicine.diagnostic_testbusiness.industryPhase contrast microscopySignificant differenceMagnetic resonance imagingBlood flowlaw.inventionSurgeryVolume (thermodynamics)Flow (mathematics)Paired sampleslawmedicine.arteryAscending aortaLeft ventricular Stroke volumeMedicineRadiology Nuclear Medicine and imagingSystolebusinessNuclear medicineRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
researchProduct

Koronare Bypassdiagnostik mit CT und MRT - eine Bestandsaufnahme

2004

The limited lifetime and the correlation between graft occlusion and recurring symptoms underline the need for repeated imaging of coronary artery bypass grafts. CT and MRI allow for non-invasive imaging of coronary bypasses with high accuracies concerning the patency of these vessels. Multidetector CT seems to be the CT technique of choice, especially after the introduction of 16 slice CT scanners for morphologic assessment of coronary artery bypass grafts. Compared with MRI, CT is a robust technique for assessment of cardiac anastomoses, native coronary arteries, and for the detection of graft stenoses. MRI, however, is able to deliver functional information about the grafts and the recip…

medicine.medical_specialtybusiness.industryIschemiaCoronary flow reserveAnastomosismedicine.diseaseAsymptomaticCoronary arteriesAnginamedicine.anatomical_structureInternal medicineOcclusionmedicineCardiologyRadiology Nuclear Medicine and imagingmedicine.symptombusinessArteryRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
researchProduct

Histopathological grading systems analysis of oral squamous cell carcinomas of young patients

2016

Background: To analyze the clinicopathological profile of young patients (≤ 40 years) with oral SCC and correlate with a control group (≥ 50 years) by means of histopathological grading systems. Material and Methods: 14 young patients and 14 control patients were selected with similar clinical stage and tumor location. Demographic and clinical data were obtained from patient records and histological sections were evaluated according to four histopathological grading systems. Associations between categories of demographic and clinical data were performed through Chi-square test and Exact Fisher test. The survival analyzes were performed according to the Kaplan-Meier method. Results: The comp…

AdultMalemedicine.medical_specialtyPathologyHistopathological gradingOdontologíaDiseaseGastroenterologyMetastasis03 medical and health sciencessymbols.namesake0302 clinical medicineInternal medicineHumansMedicineTumor locationGeneral DentistryGrading (tumors)Fisher's exact testNeoplasm StagingRetrospective StudiesOral Medicine and Pathologybusiness.industryResearch030206 dentistryPrognosismedicine.disease:CIENCIAS MÉDICAS [UNESCO]Ciencias de la saludTherapeutic modalitiesOtorhinolaryngology030220 oncology & carcinogenesisUNESCO::CIENCIAS MÉDICASCarcinoma Squamous CellsymbolsFemaleMouth NeoplasmsSurgeryNeoplasm Recurrence LocalYoung groupbusiness
researchProduct

Anthrazyklin-induzierte Kardiotoxizität: MRT des Herzens bei Kindern und Jugendlichen mit malignen Erkrankungen

2004

Purpose: Quantification of left and right ventricular function using MRI in young cancer patients treated with cardiotoxic anthracyclines. Materials and Methods: Twenty-eight patients (mean age 16.4 years) underwent cardiac MRI at 1.5 T. The study protocol consisted of morphologic T2-weighted images with fat suppression and cine steady-state free precession sequences (SSFP) for functional analysis. Seven patients were examined at the end of chemotherapy, two of them also repeatedly during therapy, and 21 patients following an average period of three years after finishing chemotherapy (range one month - 20 years) Results: The end-systolic volume index increased and the ejection fraction of t…

medicine.medical_specialtyCardiotoxicityChemotherapyEjection fractionAnthracyclinebusiness.industrymedicine.medical_treatmentCardiomyopathyCancerSteady-state free precession imagingmedicine.diseaseSurgerymedicine.anatomical_structureVentricleInternal medicinemedicineCardiologyRadiology Nuclear Medicine and imagingbusinessRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
researchProduct

Systematische Analyse der Geometrie eines definierten Kontrastmittelbolus - Implikationen für die kontrastmittelverstärkte 3D-MR-Angiographie thoraka…

2005

Purpose: Little is known about the dispersion of a defined contrast bolus during its passage through the heart and pulmonary vasculature. The purpose of this study was to analyze factors influencing a defined contrast bolus for ce-MRA of thoracic vessels. Materials and Methods: For analysis of bolus geometry, an ECG-gated saturation-recovery Turbo-Flash sequence with a TI of 20 msec was used. It was acquired axially at the level of the pulmonary trunc, so that with one data acquisition a curve analysis was possible in the ascending and descending aorta, and in the pulmonary trunc. Twenty-nine patients received 3 ml of Gd-DTPA diluted with saline to a total of 20 ml. Contrast injection was d…

Cardiac function curvemedicine.diagnostic_testbusiness.industryThoracic cavityGeometrySaline flushMagnetic resonance angiographyContrast mediumBolus (medicine)medicine.anatomical_structureDescending aortamedicine.arteryAscending aortaMedicineRadiology Nuclear Medicine and imagingbusinessRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
researchProduct

Quantification of pulmonary blood flow (PBF): validation of perfusion MRI and nonlinear contrast agent (CA) dose correction with H(2)15O positron emi…

2009

Validation of quantification of pulmonary blood flow (PBF) with dynamic, contrast-enhanced MRI is still missing. A possible reason certainly lies in difficulties based on the nonlinear dependence of signal intensity (SI) from contrast agent (CA) concentration. Both aspects were addressed in this study. Nine healthy pigs were examined by first-pass perfusion MRI using gadolinium diethylenetriamine pentaacetic acid (Gd-DTPA) and HO positron emission tomography (PET) imaging. Calculations of hemodynamic parameters were based on a one-compartment model (MR) and a two-compartment model (PET). Simulations showed a significant error when assuming a linear relation between MR SI and CA dose in the …

Gadolinium DTPAPulmonary CirculationCalibration curveSwinemedia_common.quotation_subjectGadoliniumPerfusion ImagingHemodynamicschemistry.chemical_elementContrast MediaSensitivity and SpecificityStandard deviationOxygen RadioisotopesmedicineContrast (vision)AnimalsRadiology Nuclear Medicine and imagingmedia_commonmedicine.diagnostic_testbusiness.industryReproducibility of ResultsWaterMagnetic resonance imagingImage EnhancementchemistryPositron emission tomographyPositron-Emission TomographyRadiopharmaceuticalsNuclear medicinebusinessArtifactsPerfusionMagnetic Resonance AngiographyMagnetic resonance in medicine
researchProduct