0000000000420676

AUTHOR

Patrick Pittermann

showing 2 related works from this author

Involvement of Jugular Valve Insufficiency in Cerebral Venous Air Embolism

2007

Background. Cerebral venous air entrapment is a rare finding on cranial computed tomography (CT) scan. Peripheral air embolism is discussed as a potential cause. However, the mechanism of retrograde passage through internal jugular valves and veins is unclear. Case Report. The case of a patient is reported, who had air entrapment in the left cavernous sinus. Prior to CT scanning, a peripheral intravenous line had been placed. Ultrasound revealed excessive insufficiency of the left internal jugular valve. To further study the mechanism of embolism, an echo contrast agent was injected into the cubital vein. A Valsalva maneuver resulted in retrograde transition of microbubbles across the insuf…

Adultmedicine.medical_specialtyUltrasonography Doppler Transcranialmedicine.medical_treatmentAir embolismDiagnosis DifferentialValsalva maneuvermedicineEmbolism AirHumansRadiology Nuclear Medicine and imagingSinusitisVeinInternal jugular veinbusiness.industryUltrasoundmedicine.diseasePeripheralmedicine.anatomical_structureVenous InsufficiencyEmbolismcardiovascular systemMicrobubblesFemaleNeurology (clinical)RadiologyJugular VeinsTomography X-Ray ComputedbusinessJournal of Neuroimaging
researchProduct

Therapeutic Application of 20-kHz Transcranial Ultrasound in an Embolic Middle Cerebral Artery Occlusion Model in Rats

2007

Background and Purpose— Therapeutic application of diagnostic ultrasound has been shown to improve recanalization rates in patients with acute cerebral vessel occlusion. There is experimental evidence that low-frequency ultrasound may be superior. This study was designed to evaluate the therapeutic efficacy and safety of low-frequency ultrasound in an embolic middle cerebral artery occlusion model in rats. A parameter setting was used that had not previously shown any side effects and interactions with healthy rat brain tissue. Methods— Male Wistar rats were submitted to middle cerebral artery clot embolism and transcranial treatment with 20-kHz continuous-wave ultrasound (0.2 W/cm 2 ), ei…

MaleAdvanced and Specialized Nursingbusiness.industryUltrasonic Therapymedicine.medical_treatmentUltrasoundInfarction Middle Cerebral ArteryThrombolysismedicine.diseaseRatsTranscranial DopplerDisease Models AnimalEmbolismmedicine.arteryAnesthesiaMiddle cerebral arteryOcclusionmedicineAnimalsNeurology (clinical)Rats WistarCardiology and Cardiovascular MedicinebusinessPlasminogen activatorStrokeStroke
researchProduct