0000000000429355

AUTHOR

M. Dolores Pinazo-durán

showing 4 related works from this author

Diagnostic accuracy of nonmydriatic fundus photography for the detection of glaucoma in diabetic patients.

2015

Purpose. To determine the diagnostic accuracy for glaucoma of a set of criteria with nonmydriatic monoscopic fundus photography (NMFP) in diabetics. Methods. Diabetics recruited from a screening program for diabetic retinopathy and diabetic glaucoma patients recruited from our glaucoma unit were included. Any patient with evidence of diabetic retinopathy was excluded. Diabetic patients had to have no visual field defects to be included as controls. Glaucoma patients had to have a glaucomatous field defect in at least one eye to be included. One NMFP was taken per eye for all subjects. These photographs were evaluated by two masked glaucoma specialists for the presence of the following: bila…

Malemedicine.medical_specialtyArticle Subjectgenetic structuresMedicinaGlaucomalcsh:MedicineDiagnostic accuracyDiagnostic Techniques OphthalmologicalGeneral Biochemistry Genetics and Molecular BiologyDiabetes ComplicationsPredictive Value of TestsOphthalmologyMedicineHumansAgedCIENCIAS DE LA SALUDGeneral Immunology and Microbiologymedicine.diagnostic_testbusiness.industrylcsh:RFundus photographyCase-control studyGlaucomaGeneral MedicineDiabetic retinopathyMiddle AgedControl subjectsmedicine.diseaseCiencias de la saludeye diseasesVisual fieldPatología ocularPredictive value of testsCase-Control StudiesOftalmologíaFemalesense organsbusinessResearch Article
researchProduct

Intravitreal Docosahexaenoic Acid in a Rabbit Model: Preclinical Safety Assessment

2014

PurposeThe purpose of the present study was to evaluate the retinal toxicity of a single dose of intravitreal docosahexaenoic acid (DHA) in rabbit eyes over a short-term period.MethodsSixteen New Zealand albino rabbits were selected for this pre-clinical study. Six concentrations of DHA (Brudy Laboratories, Barcelona, Spain) were prepared: 10 mg/50 µl, 5 mg/50 µl, 2'5 mg/50 µl, 50 µg/50 µl, 25 µg/50 µl, and 5 µg/50 µl. Each concentration was injected intravitreally in the right eye of two rabbits. As a control, the vehicle solution was injected in one eye of four animals. Retinal safety was studied by slit-lamp examination, and electroretinography. All the rabbits were euthanized one week a…

MaleRetinal degenerationgenetic structuresÀcids grassosPharmacologyBiochemistryMicechemistry.chemical_compoundCorneaMedicine and Health SciencesRatolinsExperimentació animalDegeneració (Patologia)Multidisciplinarymedicine.diagnostic_testQFatty AcidsChromatographic TechniquesRDegeneration (Pathology)Animal ModelsLipidsChemistrymedicine.anatomical_structureNeurologyDocosahexaenoic acidPhysical SciencesMedicineRetinal DisordersRabbitsSafetyAnatomyResearch Articlemedicine.medical_specialtyHistologyDrug Research and DevelopmentDocosahexaenoic AcidsNew Zealand AlbinoScienceOcular AnatomyResearch and Analysis MethodsRetinaInjectionsAqueous HumorModel OrganismsOcular SystemElectroretinographyToxicity Tests AcutemedicineAnimalsFatty acidsGas ChromatographyPharmacologyDose-Response Relationship Drugbusiness.industrySignificant differenceBiology and Life SciencesRetinalmedicine.diseaseSurgeryVitreous BodyOphthalmologychemistryNeuro-OphthalmologyAnimal experimentationRabbit modelClinical MedicinebusinessElectroretinographyPLoS ONE
researchProduct

Automated macular choroidal thickness measurement by swept-source optical coherence tomography in pseudoxanthoma elasticum

2016

Introduction Pseudoxanthoma elasticum (PXE) typically involves elastic fibers in blood vessels and Bruch membrane. Our purpose was to analyze retinal and choroidal macular thickness in patients with angioid streaks due PXE compared with a control group. Methods Best-corrected visual acuity (BCVA), axial length (AL), and macular swept-source optical coherence tomography were obtained. Automated segmentations of the retina and the choroid were used to obtain the corresponding thickness values. An age, gender and AL matched control group was used to compare the thickness values. Results Twelve eyes of 6 patients were included. The mean BCVA was 0.68 ± 0.29 versus 1.0 in controls (p < 0.001). T…

medicine.medical_specialtyVisual acuitygenetic structures03 medical and health scienceschemistry.chemical_compound0302 clinical medicineOptical coherence tomographyOphthalmologymedicineNeovascularizationRetinamedicine.diagnostic_testChoroidbusiness.industryRetinalPseudoxanthoma elasticummedicine.diseaseeye diseasesPXEAutomated segmentationOphthalmologyAngioid streaksChoroidal neovascularizationmedicine.anatomical_structurechemistry030221 ophthalmology & optometryOriginal Articlesense organsChoroidmedicine.symptombusiness030217 neurology & neurosurgeryInternational Journal of Retina and Vitreous
researchProduct

Smoking and age-related macular degeneration: review and update.

2013

Age-related macular degeneration (AMD) is one of the main socioeconomical health issues worldwide. AMD has a multifactorial etiology with a variety of risk factors. Smoking is the most important modifiable risk factor for AMD development and progression. The present review summarizes the epidemiological studies evaluating the association between smoking and AMD, the mechanisms through which smoking induces damage to the chorioretinal tissues, and the relevance of advising patients to quit smoking for their visual health.

medicine.medical_specialtygenetic structuresbusiness.industryMacular degenerationSmokingReview ArticleMacular degenerationmedicine.diseaseQuit smokingeye diseasesOphthalmologylcsh:Ophthalmologylcsh:RE1-994OphthalmologyInternal medicineAge relatedEpidemiologymedicineEtiologyRisk factorsense organsRisk factorbusiness
researchProduct