0000000000435528

AUTHOR

Priscilla Medina-sotomayor

Accuracy of 4 digital scanning systems on prepared teeth digitally isolated from a complete dental arch

Abstract Statement of problem The accuracy of digital scanners is acceptable for scanning a complete dental arch. However, whether that accuracy is sufficient for only 1 tooth within the dental scan of a complete dental arch is unclear. Purpose The purpose of this in vitro study was to evaluate and compare the accuracy of 4 intraoral scanners on a complete dental arch and on prepared teeth digitally isolated from the digital scan in terms of trueness and precision. Material and methods A model of a complete dental arch with tooth preparations was scanned 40 times with each of the 4 digital scanners. Their accuracy was evaluated by using 3-dimensional (3D) software to compare the test models…

research product

Two possible in vitro alternatives to evaluate the effect of gastric acid on resin-based composites

Objective: To compare two in-vitro protocols to study the effect of simulated gastric acid on the mechanical properties of resins based composites(RBCs). Three RBC FILTEK Supreme XTE (FS), BRILLIANT EverGlow (BE), GrandioSo (GS) were used. They were ran

research product

Accuracy of four digital scanners according to scanning strategy in complete-arch impressions.

STATEMENT OF PROBLEM:Although there are specific and general digital scanning guidelines depending on the system used, it is important to have the necessary flexibility in the acquisition of three-dimensional (3D) images to adapt to any clinical situation without affecting accuracy. PURPOSE:The purpose of this in vitro study was to identify and compare the scanning strategy with the greatest accuracy, in terms of trueness and precision, of four intraoral scanners in the impression of a complete dental arch. MATERIAL AND METHODS:Four digital scanners were evaluated with a 3D measuring software, using a highly accurate reference model obtained from an industrial scanner as a comparator. Four …

research product

Relationship between resolution and accuracy of four intraoral scanners in complete-arch impressions

Background The scanner does not measure the dental surface continually. Instead, it generates a point cloud, and these points are then joined to form the scanned object. This approximation will depend on the number of points generated (resolution), which can lead to low accuracy (trueness and precision) when fewer points are obtained. The purpose of this study is to determine the resolution of four intraoral digital imaging systems and to demonstrate the relationship between accuracy and resolution of the intraoral scanner in impressions of a complete dental arch. Material and methods A master cast of the complete maxillary arch was prepared with different dental preparations. Using four di…

research product