0000000000465238
AUTHOR
A. Hermanni
Photoemission of spin-polarized electrons from negative electron affinity GaAsP
GaAs0.62P0.38 activated to negative electron affinity and irradiated with circularly polarized light of a wavelength shorter than approximately 680 nm emits electrons whose spins are mainly oriented antiparallel to the photon spins. At 650 nm a degree of electron spin polarization around 40% is observed. The spectrum of spin polarization of the photoelectrons is similar to that known from GaAs cathodes but is shifted to shorter wavelengths. 25 μA current of spin-polarized electrons were achieved with a 5 mW He-Ne laser.
A new upper limit of the electron anti neutrino rest mass from tritium β-decay
Abstract A new upper limit of the electron anti neutrino rest mass has been deduced from the tritium β-decay spectrum. A source of molecular tritium has been investigated with a new solenoid retarding spectrometer. The results are m ν ϵ 2 = −38.8 ± 34.1 stat ± 15.1 syst (eV) 2 /c 4 from which we conclude m ν ϵ ≤ 7.2 eV/c 2 with 95% c.l. Our β-endpoint corresponds to a 3H-3He atomic mass difference of Δm( 3 H- 3 He) = 18590.8 ± 3 eV/c 2 (1σ) .
Improved limit on the electron-antineutrino rest mass from tritium ß-decay
Abstract The endpoint region of the β-spectrum of tritium was remeasured by an electrostatic spectrometer with magnetic guiding field. It enabled the search for a rest mass of the electron-antineutrino with improved precision. The result is m2v=−39±34stat±15syst(eV/c2)2, from which an upper limit of mv m( T )−m( 3 He )=18 591±3 eV /c 2 .
Collisional de-excitation of the metastableD-states of Ba+ by He, Ne, N2 and H2
The rate constants 〈σ · υ〉 for collisional de-excitation of the metastable 5D states of Ba+ ions have been determined in an ion trap experiment. TheD-states are selectively populated by pulsed laser excitation of the 6P1/2 or 6P3/2 state and the decay at different background pressures is monitored by the change in fluorescence intensity of the excited ions. From the pressure dependence of the decay constants we calculate the de-excitation rate constants for different collision partners, averaged over the velocity distribution of the trapped ion cloud. For He, Ne, H2 and N2 we obtain in the c.m. energy range of 0.1–0.5 eV: 〈σ·υ〉 (He)=3.0±0.2·10−13cm3/s, 〈σ·υ〉 (Ne)=5.1±0.4·10−13cm3/s, 〈σ·υ〉 (…
Precision measurement of the conversion electron spectrum of 83mKr with a solenoid retarding spectrometer
This paper reports on precision measurements of conversion lines in the decay of 83mKr with nuclear transition energies of 32.1 keV and 9.4 keV, respectively. The spectra were taken from a submonolayer surface of 83mKr frozen onto a cold backing, using the new Mainz solenoid retarding spectrometer. The high luminosity and resolution of this instrument enables the observation of all allowed conversion lines up to the N-shell and to fully separate the elastic component from inelastic satellites. The combined analysis of the data yields the transition energies Ey=32151.5±1.1 eV and 9405.9±0.8 eV, respectively. The experiment served also to pilot the application of this spectrometer to the ques…
A solenoid retarding spectrometer with high resolution and transmission for keV electrons
Abstract We have built an electrostatic electron spectrometer combining both high resolution and large luminosity. The instrument consists essentially of two superconducting solenoids separated by a system of ring electrodes of 4 m in length. Source and detector are placed in the high-field regions of the superconducting solenoids, whereas the repellent analyzing electrostatic potential of the ring electrodes peaks at the minimum of the magnetic field in between these solenoids. The magnetic guiding field provides (i) the acceptance of the full foreward solid angle of 2π, (ii) the transformation of the transverse cyclotron motion into longitudinal motion parallel to the magnetic field. The …
Stability of solid T2 films
Abstract Films of molecular tritium, physisorbed on a cold substrate, have been investigated by means of ellipsometry. A significant effect of the radioactive decay processes on the desorption kinetics and the low temperature stability of these films is not observed.