[Radiomics and artificial intelligence: new frontiers in medicine.]

2020

Radiomics is a new frontier of medicine based on the extraction of quantitative data from radiological images which can not be seen by radiologist's naked eye and on the use of these data for the creation of clinical decision support systems. The long-term goal of radiomics is to improve the non-invasive diagnosis of focal and diffuse diseases of different organs by understanding links between extracted quantitative imaging data and the underlying molecular and pathological characteristics of lesions. In the last decade, several studies have highlighted the enormous potential of radiomics in both tumoral and non-tumoral diseases of many organs and systems including brain, lung, breast, gast…

Settore ING-INF/05 - Sistemi Di Elaborazione Delle InformazioniDiagnostic ImagingRadiomicsArtificial IntelligenceNeoplasmsHumansPrecision MedicineSettore MED/36 - Diagnostica Per Immagini E RadioterapiaDecision Support Systems ClinicalImagingRecenti progressi in medicina
researchProduct

TRANSCRANIAL MAGNETIC RESONANCE-GUIDED FOCUSED ULTRASOUND (TCMRGFUS) CON SCANNER DA 1.5T: NOTA TECNICA

2018

Scopo La terapia dei disordini neurologici mediante tcMRgFUS è stata effettuata utilizzando esclusivamente scanner RM da 3T. Utilizzando uno scanner RM da 1.5T la qualità delle sequenze morfologiche utilizzabili per la pianificazione di questi trattamenti è risultata essere soddisfacente utilizzando la bobina body RF (quella utilizzata con scanner 3T). Tuttavia l'SNR delle sequenze utilizzate per la termometria RM è risultato inferiore allo standard accettabile per i trattamenti. È stata quindi sviluppata una bobina a 2 canali per assicurare un adeguato SNR. Presentiamo il protocollo di imaging efficacemente utilizzato per eseguire procedure tcMRgFUS con il primo sistema mai integrato …

ultrasuoni focalizzati risonanza magnetica signal-to-noise ratioSettore MED/37 - NeuroradiologiaSettore MED/36 - Diagnostica Per Immagini E RadioterapiaSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)
researchProduct

MDCT Enteroclysis and Enterography

2015

Since the first studies suggesting its possible role in the management of Crohn’s disease patients, multidetector computed tomography has usually been considered a useful diagnostic technique in Crohn’s disease for the detection of extraenteric complications, as intra-abdominal abscesses, the study of strictures, prestenotic dilatations, fistulas, and postsurgical complications. Moreover, it is a widely available technique and is considered the gold standard in emergency.

Crohn’s diseasemedicine.medical_specialtyCrohn's diseasebusiness.industryPrestenotic dilatationGold standard (test)medicine.diseaseMagnetic resonance enterographyMultidetector computed tomographymedicineRadiologyPostsurgical complicationsbusinessBowel wall
researchProduct