A completely automated CAD system for mass detection in a large mammographic database

2006

Mass localization plays a crucial role in computer-aided detection (CAD) systems for the classification of suspicious regions in mammograms. In this article we present a completely automated classification system for the detection of masses in digitized mammographic images. The tool system we discuss consists in three processing levels: (a) Image segmentation for the localization of regions of interest (ROIs). This step relies on an iterative dynamical threshold algorithm able to select iso-intensity closed contours around gray level maxima of the mammogram. (b) ROI characterization by means of textural features computed from the gray tone spatial dependence matrix (GTSDM), containing secon…

Contextual image classificationPixelDatabasemedicine.diagnostic_testComputer scienceImage processingGeneral MedicineImage segmentationmedicine.diseasecomputer.software_genreBreast cancerImage textureComputer-aided diagnosismedicineMedical imagingMammographycomputerMedical Physics
researchProduct

A test to evaluate the impact of the CAD tools in mammographic diagnosis

2003

In this work we present the results of a study about the impact of CAD tools on Sensitivity and Specificity in mammographic diagnosis. The approach is aimed to evaluate the statistical significance through the comparison of these figures of merit obtained in different situations. For this purpose two different CAD tools, the CALMA station (INFN project) and the SecondLook™ station (by CADx) have been used as a support for radiologists.

medicine.medical_specialtyCad toolsComputer sciencemedicineMedical physicsSensitivity (control systems)Test (assessment)
researchProduct

FLUXEN portable equipment for direct X-ray spectra measurements

2004

Abstract The proper use of imaging equipment in radiological units is based on an appropriate knowledge of the physical characteristics of the X-ray beam used. The FLUXEN PROJECT is working on a portable apparatus which, together with dedicated software, is able to perform an exact spectral reconstruction of the radiation produced in diagnostic X-ray tubes. The apparatus characterizes the energy spectrum of radiological tubes and also provides a measurement of the emitted flux. The acquisition system is based on a commercial CZT detector (3×3×2 mm 3 ), produced by AMPTEK, cooled by a Peltier cell, with a high efficiency in the diagnostic X-ray energy range and modified in the shaping electr…

PhysicsNuclear and High Energy PhysicsRange (particle radiation)X-ray spectraX ray spectrographs X rays air kerma CZTbusiness.industryRadiationSignalSpectral lineCZTOpticsSoftwareX-ray spectra; direct measurement; CZTElectronicsdirect measurementbusinessInstrumentationBeam (structure)Energy (signal processing)
researchProduct

GPCALMA, a mammographic CAD in a GRID connection

2003

Purpose of this work is the development of an automatic system which could be useful for radiologists in the investigation of breast cancer. A breast neoplasia is often marked by the presence of microcalcifications and massive lesions in the mammogram: hence the need for tools able to recognize such lesions at an early stage. GPCALMA (Grid Platform Computer Assisted Library for MAmmography), a collaboration among italian physicists and radiologists, has built a large distributed database of digitized mammographic images (at this moment about 5500 images corresponding to 1650 patients). This collaboration has developed a CAD (Computer Aided Detection) system which, installed in an integrated…

Engineering drawingMultimediaDistributed databasemedicine.diagnostic_testbepress|Physical Sciences and Mathematics|PhysicsComputer scienceComputingMethodologies_IMAGEPROCESSINGANDCOMPUTERVISIONFOS: Physical sciencesCADGeneral Medicinecomputer.software_genreGridPhysics - Medical PhysicsComputer aided detectionBreast cancerGrid connectionmedicineComputer Aided DesignMammographyCADMedical Physics (physics.med-ph)GRIDcomputerBreast cancer; CAD; GRIDDigitization
researchProduct

Odderon Exchange from Elastic Scattering Differences between pp and pp¯ Data at 1.96 TeV and from pp Forward Scattering Measurements

2021

We describe an analysis comparing the p p ¯ elastic cross section as measured by the D0 Collaboration at a center-of-mass energy of 1.96 TeV to that in p p collisions as measured by the TOTEM Collaboration at 2.76, 7, 8, and 13 TeV using a model-independent approach. The TOTEM cross sections, extrapolated to a center-of-mass energy of s = 1.96 TeV , are compared with the D0 measurement in the region of the diffractive minimum and the second maximum of the p p cross section. The two data sets disagree at the 3.4 σ level and thus provide evidence for the t -channel exchange of a colorless, C -odd gluonic compound, also known as the odderon. We combine these results with a TOTEM analysis of th…

Quantum chromodynamicsPhysicsElastic scatteringParticle physics010308 nuclear & particles physicsForward scatterScatteringStrong interactionGeneral Physics and Astronomy01 natural sciencesScattering amplitudeCross section (physics)0103 physical sciences010306 general physicsBar (unit)Physical Review Letters
researchProduct

GPCALMA: An Italian mammographic database of digitized images for research

2006

In this work the implementation of a database of digitized mammograms is described. The digitized images were collected since 1999 by a community of physicists in collaboration with radiologists in several Italian hospitals, as a first step in order to develop and implement a Computer Aided Detection (CAD) system. 3369 mammograms were collected from 967 patients; they were classified according to the type and the morphology of the lesions, the type of the breast tissue and the type of pathologies. A dedicated Graphical User Interface was developed for mammography visualization and processing, in order to support the medical diagnosis directly on a high-resolution screen. The database has be…

medicine.diagnostic_testDatabasePoint (typography)business.industryComputer scienceInvasive Lobular Carcinoma Grid Technology Mammographic Image Digitize Mammogram Italian HospitalComputingMethodologies_IMAGEPROCESSINGANDCOMPUTERVISIONCADcomputer.software_genreVisualizationGrid computingmedicineMedical imagingMammographyMedical diagnosisbusinesscomputerGraphical user interface
researchProduct

MAGIC-5: an Italian mammographic database of digitised images for research

2008

The implementation of a database of digitised mammograms is discussed. The digitised images were collected beginning in 1999 by a community of physicists in collaboration with radiologists in several Italian hospitals as a first step in developing and implementing a computer-aided detection (CAD) system. All 3,369 mammograms were collected from 967 patients and classified according to lesion type and morphology, breast tissue and pathology type. A dedicated graphical user interface was developed to visualise and process mammograms to support the medical diagnosis directly on a high-resolution screen. The database has been the starting point for developing other medical imaging applications,…

AdultLesion typeDatabases Factualmammographic databaseBreast NeoplasmsCADcomputer.software_genreSensitivity and SpecificityDatabaseMedical imagingHumansMedicineMammographyRadiology Nuclear Medicine and imagingGridMedical image processingMedical diagnosisAgedRetrospective StudiesGraphical user interfacecomputer assisted detectionDatabasePoint (typography)medicine.diagnostic_testbusiness.industryMagic (programming)General MedicineMiddle Agedimage processingRadiographic Image EnhancementItalyRadiographic Image Interpretation Computer-AssistedFemaleTomography X-Ray Computedbusinessdatabase; mammography; medical image processing; gridcomputerMammographyLa radiologia medica
researchProduct

Comparison of two portable solid state detectors with an improved collimation and alignment device for mammographic x-ray spectroscopy

2006

We describe a portable system for mammographic x-ray spectroscopy, based on a 2 X 2 X 1 mm3 cadmium telluride (CdTe) solid state detector, that is greatly improved over a similar system based on a 3 X 3 X 2 mm3 cadmium zinc telluride (CZT) solid state detector evaluated in an earlier work. The CdTe system utilized new pinhole collimators and an alignment device that facilitated measurement of mammographic x-ray spectra. Mammographic x-ray spectra acquired by each system were comparable. Half value layer measurements obtained using an ion chamber agreed closely with those derived from the x-ray spectra measured by either detector. The faster electronics and other features of the CdTe detecto…

Materials sciencebusiness.industryDetectorX-ray detectorGeneral MedicineCadmium telluride photovoltaicsCollimated lightCadmium zinc telluridechemistry.chemical_compoundOpticschemistryIonization chamberPinhole (optics)businessHalf-value layerMedical Physics
researchProduct