Purpose To establish the possible beneficial effects of three synthetic antioxidants: S-adenosil-L-methionine (SAMe), N-acetyl-L-cysteine (NAC) and Ebselen in optic nerve damage following chronic ethanol feeding in adult rats. Methods Twenty male Sprague-Dawley rats (five groups of four animals each) were fed a liquid, ethanol-containing diet with littermates given isocaloric amounts of ethanol-free diet serving as controls. Antioxidants were administered by dissolving them in the liquid diet at 0.4 mg/ml (SAMe), 0.163 mg/ml (NAC) and 5.33 mg/ml (Ebselen). After 6 weeks, optic nerves were obtained and parameters that are relevant for the modulation of oxidative stress, such as antioxidants …

research product

Evaluation of the performance of multifocal intraocular lenses image quality: analysis of the standard methods

Purpose: To analyze the standard methods used to describe intraocular lenses (IOL) and to suggest some improvements to make them applicable for multifocal IOLs. Methods: The EN-ISO standards and the standards of the American National Standards Institute (ANSI) for the evaluation of the performance of IOLs are tested for multifocal IOLs. The MTF of the one refractive multifocal IOL and two hybrid refractive-diffractive multifocal IOLs is measured for both distance focus and near focus and using different pupil sizes. Results: The average modulation (AM) from 0 to 100 c/mm of multifocal IOLs (for the distance focus) is about 40-50% lower than the AM of monofocal IOLs, for all pupil sizes stud…

research product

Modulation transfer function in refractive-diffractive multifocal intraocular lenses in vitro

Purpose: The optical quality of two types of multifocal, hybrid refractive-diffractive, intraocular lenses (IOL) is analyzed in vitro. Following the EN-ISO international standard, the IOLs’ modulation transfer functions (MTF) are determined for both distance and near vision. The behaviour of these curves when the pupil size varies is studied. Methods: The IOLs analyzed were: AcrySoft ResTor SN60D3 (Alcon) and Tecnis ZM900 (AMO). The MTF was calculated from the cross line-spread function recorded with the OPAL Vector System (Image Science Ltd. Oxford) by using fast Fourier transform techniques. The artificial eye model used simulates in vivo conditions of the anterior chamber including an ar…

research product

Are Ocular Response Analyzer useful to measure corneal hysteresis in patients with intracorneal rings?

Purpose Corneal hysteresis is a viscoelastic property characterized by the difference in behavior under loading and unloading. The aim of the study was to determine corneal hysteresis in different eyes: healthy eyes, keratoconic eyes and keratoconic eyes after intracorneal ring implants. Methods This study comprised 95 eyes of 59 patients. The study population was divided into 3 groups. We analyze 30 healthy human eyes, 35 keratoconic eyes (Amsler grade II-III) and 30 keratoconic eyes after intracorneal rings implantation. Corneal biomechanical properties of these eyes were measured with the Ocular Response Analyser (ORA-Reichert) according to two parameters: corneal hysteresis (CH) and cor…

research product