0000000000508659

AUTHOR

Purificación López-mahía

Automated on-line in-tube solid-phase microextraction-assisted derivatization coupled to liquid chromatography for quantifying residual dimethylamine in cationic polymers.

Abstract A method for the analysis of dimethylamine (DMA) by automated in-tube solid-phase microextraction (IT-SPME)-supported chemical derivatization coupled with high-performance liquid chromatography was developed. Extraction, derivatization and desorption were studied by using a capillary coated with 95% polydimethylsiloxane and 5% polydiphenylsiloxane. Solution derivatization and automated IT-SPME derivatization using 9-fluorenylmethyl chloroformate (FMOC) were compared. The proposed procedure provided adequate linearity, accuracy and precision in the 0.2–2.0 μg/mL concentration interval, and the limit of detection (LOD) was 50 ng/mL. The main advantages of the proposed procedure are: …

research product

In-tube solid-phase microextraction and liquid chromatography using a monolithic column for the selective determination of residual ethylenediamine in industrial cationic polymers.

The selective determination of the diamine ethylenediamine (EDA) in the presence of a higher amount of residual dimethylamine in cationic polymers has been developed. The strategy uses both a solution derivatization with a selective agent of primary amines such as o-phthaldialdehyde-N-acetyl-L-cysteine (OPA-NAC) and an in-tube solid-phase microextraction (IT-SPME) coupled to liquid chromatography (LC). A 70 cm long, 0.32 mm internal diameter, and 3 microm thick commercially available capillary column coated with 95% polydimethylsiloxane and 5% polydiphenylsiloxane was employed to replace the injection loop of a Rheodyne injection valve. A volume of 1 mL of derivatized sample was passed thro…

research product

Ion-pair in-tube solid-phase microextraction and capillary liquid chromatography using a titania-based column: application to the specific lauralkonium chloride determination in water.

Abstract A quick, miniaturized and on-line method has been developed for the determination in water of the predominant homologue of benzalkonium chloride, dodecyl dimethyl benzyl ammonium chloride or lauralkonium chloride (C 12 -BAK). The method is based on the formation of an ion-pair in both in-tube solid-phase microextraction (IT-SPME) and capillary liquid chromatography. The IT-SPME optimization required the study of the length and nature of the stationary phase of capillary and the processed sample volume. Because to the surfactant character of the analyte both, the extracting and replacing solvents, have played a decisive role in the IT-SPME optimized procedure. Conditioning the capil…

research product

On-line analysis of carbonyl compounds with derivatization in aqueous extracts of atmospheric particulate PM10 by in-tube solid-phase microextraction coupled to capillary liquid chromatography.

Abstract A new device for carbonyl compounds based on coupling on-line and miniaturizing both, sample pretreatment and chromatographic separation, is reported. Two capillary columns, a GC capillary column (95% methyl–5% phenyl substituted backbone, 70 cm × 0.32 mm i.d., 3 μm film thickness) in the injection valve for in-tube solid-phase microextraction (IT-SPME) and a Zorbax SB C18 (150 mm × 0.5 mm i.d., 5 μm particle diameter) LC capillary column were employed. Different combinations of IT-SPME and derivatization using 2,4-dinitrophenylhydrazine (DNPH) were examined for mixtures containing 15 carbonyl compounds (aliphatic, aromatic and unsaturated aldehydes and ketones). A screening analys…

research product

Determination of carbonyl compounds in particulate matter PM2.5 by in-tube solid-phase microextraction coupled to capillary liquid chromatography/mass spectrometry.

Abstract In this paper, a new procedure based on in-tube solid phase microextraction (IT-SPME)-capillary liquid chromatography hyphenated to mass spectrometry detection by using microelectrospray ionisation (CapLC–MS), has been reported. The device was proposed to quantify 12 carbonyl compounds (10 aliphatic aldehydes, an unsaturated aldehyde and a ketone) derivatized with 2,4-dinitrophenylhidrazine (DNPH) reagent in aqueous extracts of PM 2.5 . This methodology involves the on-line preconcentration of DNPH-carbonyl compounds derivatives coupled to the CapLC–MS system, efficiently providing appropriate sensitivity for the determination of the target analytes. Detection limits for the analyt…

research product

Rapid evaluation of ammonium in different rain events minimizing needed volume by a cost-effective and sustainable PDMS supported solid sensor.

Abstract The presence of ammonium ion in rainwater is due to atmospheric processes which involve its scavenging from gas phase and particulate matter. The fractionated samplings of rainwater can provide information about these processes and their potential sources. However, only a low sample volume may be available, which constrained the analysis in general and more particularly in situ mode. For minimizing this limitation, this work proposes a polydimethylsiloxane (PDMS)-salicylate sensor that produces a color change. The embedding of solid reagents into PDMS was optimized. Good analytical characteristics (analysis time of 10 min, sample volume of 500 μL, limit of detection 0.03 μgmL−1) we…

research product