Ali S. Meigooni
SU-FF-T-15: Comparison of Various Monte Carlo Codes for Brachytherapy Source Dosimetry
Purpose: Monte Carlo simulations are used for dosimetric evaluation of brachytherapysources. Various investigators had demonstrated good agreement between the measured and simulated data while some others have shown discrepancies between the two methods. These discrepancies were attributed to the errors in cross section data, differences in phantom and source geometry and composition. However, the exact causes of these differences have not yet fully explored. The goal of this project is to verify the differences among the widely available Monte Carlo codes for brachytherapysourcedosimetry.Material and method: These investigations are based on VariSource 192 Ir , Model VS2000, IsoAid Advanta…
Erratum: “TG-43 U1 based dosimetric characterization of model 67-6520 Cs-137 brachytherapy source”
Purpose: Brachytherapy treatment has been a cornerstone for management of various cancer sites, particularly for the treatment of gynecological malignancies. In low dose rate brachytherapy treatments,C137s sources have been used for several decades. A new C137s source design has been introduced (model 67-6520, source B3-561) by Isotope Products Laboratories (IPL) for clinical application. The goal of the present work is to implement the TG-43 U1 protocol in the characterization of the aforementioned C137s source. Methods: The dosimetriccharacteristics of the IPLC137s source are measured using LiF thermoluminescent dosimeters in a Solid Water™ phantom material and calculated using Monte Carl…
Supplement 2 for the 2004 update of the AAPM Task Group No. 43 Report: Joint recommendations by the AAPM and GEC-ESTRO
Since publication of the 2004 update to the American Association of Physicists in Medicine (AAPM) Task Group No. 43 Report (TG-43U1) and its 2007 supplement (TG-43U1S1), several new low-energy photon-emitting brachytherapy sources have become available. Many of these sources have satisfied the AAPM prerequisites for routine clinical purposes and are posted on the Brachytherapy Seed Registry managed jointly by the AAPM and the Imaging and Radiation Oncology Core Houston Quality Assurance Center (IROC Houston). Given increasingly closer interactions among physicists in North America and Europe, the AAPM and the Groupe Europeen de Curietherapie-European Society for Radiotherapy & Oncology (GEC…
TG-43U1-based dosimetric characterization of model 67-6520 137 Cs brachytherapy source
Erratum: “Supplement 2 for the 2004 update of the AAPM Task Group No. 43 Report: Joint recommendations by the AAPM and GEC-ESTRO” [Med. Phys. Vol 44 (9), e297-e338 (2017)]
Dosimetric characterization of Ir-192 LDR elongated sources
Ir-192 wires have been used in low-dose-rate brachytherapy for many years. Commercially available treatment planning systems approximate the dose rate distribution of the straight or curved wires applying the superposition principle using one of the following methods: (i) The wire is modeled as a set of point sources, (ii) the wire is modeled as a set of small straight segment wires, (iii) the values of the parameters and functions of the American Association of Physicists in Medicine (AAPM) Task Group 43 protocol are obtained for wire lengths between 3 and 7 cm assuming some simplifications. The dose rate distributions obtained using these methods for linear wires of different lengths and …