0000000000521681

AUTHOR

F. D’errico

Phenol compounds as new materials for electron spin resonance dosimetry in radiotherapy

Introduction: Among the various dosimetric techniques used for characterizing the radiation beams used in radiation therapy, the electron spin resonance (ESR) arouses increasing interest for applications in various therapy procedures. Free radicals are known to be produced when a compound is irradiated with ionizing radiations. The concentration of radiationinduced free radicals is proportional to the absorbed dose and this allows for dosimetric measurements through ESR technique which enables to quantitatively determine the radical concentration. In this work we report the ESR investigation of phenol pellets and thin films exposed to various types of radiation beams (clinical photon and el…

research product

Diffusion and sensitivity characteristics of a chemically cross-linked PVA-Fricke gel dosimeter

Introduction: Current radiotherapy techniques implement treatment plans based on volumetric distributions of dose with complex shapes and sharp gradients. The agreement between these plans and the dose that is truly delivered is very challenging to verify. Thus, there is the need for a dosimetric system that is truly three dimensional, sensitive to radiation in each point and tissue equivalent. In this framework, great interest is encountered by radio-chromic gel dosimeters. In order to address the limitations of gels based on natural matrices, some investigators have proposed dosimeters based on poly vinyl alcohol (PVA) made by freezing-thawing cycles. Even though these gels have a low dif…

research product

Sensibilità e stabilità dei dosimetri gel di tipo Fricke esposti ai fotoni nel range clinico in funzione della concentrazione di ferro e degli additivi presenti: 3D MRI per applicazioni dosimetriche

research product

Misure preliminari su scanner MRI 7T di stabilità nel tempo di Dosimetri gel di tipo Fricke

L’ottimizzazione delle procedure che utilizzano radiazioni ionizzanti in campo medico costituisce un elemento chiave per la sicurezza del paziente e l’esito dei trattamenti radioterapici. In particolare è fondamentale arrecare il minor danno possibile ai tessuti sani circostanti la neoplasia da trattare (Attix, 2004). La misurazione precisa della dose somministrata nei tessuti e la sua mappatura in tre dimensioni sono di fondamentale importanza in termini di riuscita e di pianificazione dei trattamenti radioterapici (Khan, 2009). In questo lavoro sono presentate le misure preliminari effettuate per testare la stabilità temporale di dosimetri gel di tipo Fricke tramite scanner pre-clinico 7T…

research product

NUCLEAR MAGNETIC RESONANCE RELAXOMETRY AND IMAGING FOR DOSIMETRY WITH AGAROSE FRICKE GEL

Introduction: Fricke Xylenol Gel (FXG) dosimetric system is based on the radiation induced oxidation of ferrous to ferric ions. In this kind of gels it can occur that ferrous and ferric ions diffuse in the gel matrix. To preserve the spatial distribution of the dose from diffusion, Fricke gels must be undergoing measurement within a few hours of their irradiation. Thus, the spatial integrity of the dose distribution in the Fricke gel is maintained. The oxidation of ferrous ions also causes a reduction of the longitudinal nuclear magnetic relaxation time which can be measured by means of nuclear magnetic resonance (NMR) instrumentation. In this work we performed NMR relaxometry and MR imagin…

research product

New Fricke gel with high sensitivity and low diffusion for 3D-MRI dosimetry

research product

Characterization of Fricke gel dosimeters exposed to clinical photons beams and of MRI dosimetrical applications

research product

Studio e calibrazione della risposta ottica ed NMR di dosimetri gel di tipo Fricke (FXG) in campi misti neutroni-gamma per applicazioni cliniche

research product

Dating of Brazilian shells through electron paramagnetic resonance

In the present work we report dating procedure of these shells by using the electron paramagnetic resonance. The first step of the analysis was the definition of the optimal procedure for sample preparation. At this aim the analysis of the sample composition was carried out by X-ray fluorescence (XRF) measurements and an accurate analysis was study on the effect of the chemical etching with varying typology and concentration of acid to be used for removing the external layer of shells which are affected by alpha particles.

research product

NEW FRICKE GEL WITH HIGH SENSITIVITY AND LOW DIFFUSION FOR3D-MRI DOSIMETRY

research product

PVA-GTA Fricke gel dosimeters exposed to clinical photons beams: Nuclear Magnetic Resonance Relaxometry and Imaging

Fricke Gel (FXGs) dosimetric system is based on the radiation induced oxidation of ferrous to ferric ions. The application of Fricke gels for ionizing radiation dosimetry is continuously increasing worldwide due to their many favorable properties. However, one of their shortcomings is that ferrous and ferric ions diffuse in the gel matrix. To maintain the spatial integrity of the dose distribution, Fricke gels must be undergoing measurement within a few hours of their irradiation, so that ferric ions remain close to their point of production. Thus, the spatial integrity of the dose distribution in the Fricke gel is maintained (Schreiner, 2015). The gel matrix also contributes to the oxidati…

research product