0000000000530479

AUTHOR

P. Von Ballmoos

SPI/INTEGRAL in-flight performance

The SPI instrument has been launched on-board the INTEGRAL observatory on October 17, 2002. SPI is a spectrometer devoted to the sky observation in the 20 keV-8 MeV energy range using 19 germanium detectors. The performance of the cryogenic system is nominal and allows to cool the 19 kg of germanium down to 85 K with a comfortable margin. The energy resolution of the whole camera is 2.5 keV at 1.1 MeV. This resolution degrades with time due to particle irradiation in space. We show that the annealing process allows the recovery of the initial performance. The anticoincidence shield works as expected, with a low threshold at 75 keV, reducing the GeD background by a factor of 20. The digital …

research product

The e-ASTROGAM gamma-ray space observatory for the multimessenger astronomy of the 2030s

e-ASTROGAM is a concept for a breakthrough observatory space mission carrying a gamma-ray telescope dedicated to the study of the non-thermal Universe in the photon energy range from 0.15 MeV to 3 GeV. The lower energy limit can be pushed down to energies as low as 30 keV for gamma-ray burst detection with the calorimeter. The mission is based on an advanced space-proven detector technology, with unprecedented sensitivity, angular and energy resolution, combined with remarkable polarimetric capability. Thanks to its performance in the MeV-GeV domain, substantially improving its predecessors, e-ASTROGAM will open a new window on the non-thermal Universe, making pioneering observations of the…

research product

SPI/INTEGRAL observation of the Cygnus region

We present the analysis of the first observations of the Cygnus region by the SPI spectrometer onboard the Integral Gamma Ray Observatory, encompassing ${\sim}$ 600 ks of data. Three sources namely Cyg X-1, Cyg X-3 and EXO 2030+375 were clearly detected. Our data illustrate the temporal variability of Cyg X-1 in the energy range from 20 keV to 300 keV. The spectral analysis shows a remarkable stability of the Cyg X-1 spectra when averaged over one day timescale. The other goal of these observations is SPI inflight calibration and performance verification. The latest objective has been achieved as demonstrated by the results presented in this paper.

research product

INTEGRAL/SPI ground calibration

Three calibration campaigns of the spectrometer SPI have been performed before launch in order to determine the instrument characteristics, such as the effective detection area, the spectral resolution and the angular resolution. Absolute determination of the effective area has been obtained from simulations and measurements. At 1 MeV, the effective area is 65 cm^2 for a point source on the optical axis, the spectral resolution ~2.3 keV. The angular resolution is better than 2.5 deg and the source separation capability about 1 deg. Some temperature dependant parameters will require permanent in-flight calibration.

research product

The FIGARO II experiment: a general outline of the mission and the principal scientific results

The FIGARO II (French Italian Gamma-Ray Observatory) experiment has been launched successfully three times: in July 1986 from Milo (Trapani), in November 1988 from Charleville (Australia) and in July 1990 again from Milo. In the first flight the observational program was limited to the Crab pulsar PSR0531+21 only because of a telemetry failure: the high sensitivity of FIGARO II allowed an accurate study of the pulse shape as well as a phase-resolved spectroscopy. It was also possible to evaluate the dispersion measure of the Crab pulsar at the flight date from the time delay between gamma-ray and radio pulses. The major results of the second flight were a stringent upper limit to the low-en…

research product

SPI: The spectrometer aboard INTEGRAL

SPI is a high spectral resolution gamma-ray telescope on board the ESA mission INTEGRAL (International Gamma Ray Astrophysics Laboratory). It consists of an array of 19 closely packed germanium detectors surrounded by an active anticoincidence shield of BGO. The imaging capabilities of the instrument are obtained with a tungsten coded aperture mask located 1.7 m from the Ge array. The fully coded field-of-view is 16º, the partially coded field of view amounts to 31º, and the angular resolution is 2.5º. The energy range extends from 20 keV to 8 MeV with a typical energy resolution of 2.5 keV at 1.3 MeV. Here we present the general concept of the instrument followed by a brief description of …

research product