0000000000550114

AUTHOR

Tetsuo Iguchi

Development of High Resolution Resonance Ionization Mass Spectrometry for Neutron Dosimetry Technique with93Nb(n,n')93mNb Reaction

We have proposed an advanced technique to measure the 93mNb yield precisely by Resonance Ionization Mass Spectrometry, instead of conventional characteristic X-ray spectroscopy. 93mNb-selective resonance ionization is achievable by distinguishing the hyperfine splitting of the atomic energy levels between 93Nb and 93mNb at high resolution. In advance of 93mNb detection, we could successfully demonstrate high resolution resonant ionization spectroscopy of stable 93Nb using an all solid-state, narrowband and tunable Ti:Sapphire laser system operated at 1 kHz repetition rate. peerReviewed

research product

Development of resonance ionization in a supersonic gas-jet for studies of short-lived and long-lived radioactive nuclei

High-resolution resonance ionization spectroscopy (RIS) is required for laser spectroscopy and trace analysis of short-lived and long-lived radioactive nuclei. We have proposed high-resolution resonance ionization spectroscopy in a gas jet combined with a narrow band-width injection-locked Ti:Sapphire laser. Resonance ionization of stable 93Nb in a gas jet was demonstrated using a broad bandwidth Ti:Sapphire laser. In addition, a setup for high-resolution RIS in a gas-jet was designed using numerical simulations of the gas-jet conditions based on computational fluid dynamics.

research product

Development of two-color resonance ionization scheme for Th using an automated wide-range tunable Ti:sapphire laser system

Two-color resonance ionization schemes of Th were investigated by an automated wide-range tunable, grating-assisted Ti:Sa laser system with intracavity SHG option. A two-color ionization scheme via autoionizing state (1st step: 372.049 nm and 2nd step: 401.031 nm) was developed and its relative efficiency was lower by factor of three compared to a known three color scheme. peerReviewed

research product

Development of a sequential data correction method for isotope ratio analysis by resonance ionization mass spectrometry

A sequential data correction method using several experimental parameters of pulsed resonance ionization mass spectrometry was developed to reduce mass discrimination effects for isotope ratio analysis as well as fluctuations in the ion count rate. This correction method was applied to isotope ratio determination of stable titanium isotopes using a two-step, single color ionization scheme. A significant improvement of the precision of the measured isotopic ratio of stable titanium isotopes was demonstrated after correction with a parameter set consisting of laser power, atmospheric pressure, and laser frequency.

research product

Development of accelerator mass spectrometry assisted by isotope-selective laser photodetachment for monitoring 129I

Abstract A prototype system was developed to investigate an isotope-selective laser photodetachment technique for a 129 I accelerator mass spectrometer. A pulsed ion source for negative iodine ions (I − ) that employed laser ablation proved to be suitable for isotope-selective laser photodetachment. Laser photodetachment of pulsed negative iodine ions was estimated to have an efficiency of about 81% based on a model calculation for the prototype system with a tunable pulsed Ti:sapphire laser.

research product