0000000000555826
AUTHOR
A. Picard
Micro-optical components for parallel optical networks
Key components for parallel optical links are fabricated cost-effectively using LIGA technology. Multifiber ferrules and mechanical splices, 1/spl times/2 and 4/spl times/4 single-mode matrix switches and micro lens arrays with passive alignment structures are presented.
A new upper limit of the electron anti neutrino rest mass from tritium β-decay
Abstract A new upper limit of the electron anti neutrino rest mass has been deduced from the tritium β-decay spectrum. A source of molecular tritium has been investigated with a new solenoid retarding spectrometer. The results are m ν ϵ 2 = −38.8 ± 34.1 stat ± 15.1 syst (eV) 2 /c 4 from which we conclude m ν ϵ ≤ 7.2 eV/c 2 with 95% c.l. Our β-endpoint corresponds to a 3H-3He atomic mass difference of Δm( 3 H- 3 He) = 18590.8 ± 3 eV/c 2 (1σ) .
Improved limit on the electron-antineutrino rest mass from tritium ß-decay
Abstract The endpoint region of the β-spectrum of tritium was remeasured by an electrostatic spectrometer with magnetic guiding field. It enabled the search for a rest mass of the electron-antineutrino with improved precision. The result is m2v=−39±34stat±15syst(eV/c2)2, from which an upper limit of mv m( T )−m( 3 He )=18 591±3 eV /c 2 .
Precision measurement of the conversion electron spectrum of 83mKr with a solenoid retarding spectrometer
This paper reports on precision measurements of conversion lines in the decay of 83mKr with nuclear transition energies of 32.1 keV and 9.4 keV, respectively. The spectra were taken from a submonolayer surface of 83mKr frozen onto a cold backing, using the new Mainz solenoid retarding spectrometer. The high luminosity and resolution of this instrument enables the observation of all allowed conversion lines up to the N-shell and to fully separate the elastic component from inelastic satellites. The combined analysis of the data yields the transition energies Ey=32151.5±1.1 eV and 9405.9±0.8 eV, respectively. The experiment served also to pilot the application of this spectrometer to the ques…
A solenoid retarding spectrometer with high resolution and transmission for keV electrons
Abstract We have built an electrostatic electron spectrometer combining both high resolution and large luminosity. The instrument consists essentially of two superconducting solenoids separated by a system of ring electrodes of 4 m in length. Source and detector are placed in the high-field regions of the superconducting solenoids, whereas the repellent analyzing electrostatic potential of the ring electrodes peaks at the minimum of the magnetic field in between these solenoids. The magnetic guiding field provides (i) the acceptance of the full foreward solid angle of 2π, (ii) the transformation of the transverse cyclotron motion into longitudinal motion parallel to the magnetic field. The …
Mosaic-activating FGFR2 mutation in two fetuses with papillomatous pedunculated sebaceous naevus
International audience; Papillomatous pedunculated sebaceous naevus (PPSN) has been described as a subtype of sebaceous naevus (SN), typically affecting the scalp and face. In contrast with Schimmelpenning syndrome, no cerebral, ocular or skeletal anomalies have hitherto been reported. We report two unrelated fetuses with PPSN, one with large pink exophytic tumours, the other with minor features but similar microscopic findings. We performed whole-exome sequencing in affected skin tissue from fetus 1, which identified a postzygotic de novo FGFR2 c.1144T>C (p.Cys382Arg) mutation in 34[middle dot]6% of reads which was absent in the parents' blood. Targeted deep sequencing of FGFR2 confirmed i…