0000000000578579
AUTHOR
J. Herrmann
SARS-CoV-2 vaccination modelling for safe surgery to save lives: data from an international prospective cohort study
Abstract Background Preoperative SARS-CoV-2 vaccination could support safer elective surgery. Vaccine numbers are limited so this study aimed to inform their prioritization by modelling. Methods The primary outcome was the number needed to vaccinate (NNV) to prevent one COVID-19-related death in 1 year. NNVs were based on postoperative SARS-CoV-2 rates and mortality in an international cohort study (surgical patients), and community SARS-CoV-2 incidence and case fatality data (general population). NNV estimates were stratified by age (18–49, 50–69, 70 or more years) and type of surgery. Best- and worst-case scenarios were used to describe uncertainty. Results NNVs were more favourable in su…
The campomelic syndrome: review, report of 17 cases, and follow-up on the currently 17-year-old boy first reported by Maroteaux et al in 1971.
We report 17 cases of the campomelic syndrome (CS) and a follow-up of one of the original patients of Maroteaux et al who is now 17 years old. Our review is based on 97 patients, including our own. An infant with the CS presents at birth with spectacularly short and bowed femora and tibiae. The initial chest radiograph confirms the diagnosis by demonstrating extremely small bladeless scapulae and hypoplastic pedicles of many thoracic vertebrae. Ossification of the sternal segments, pubis, talus, and knee epiphyses is also retarded. Usually the hips are dislocated and talipes equinovarus deformities are present. There is a small chondrocranium and a disproportionately large neurocranium. The…
Elastic and inelastic photon scattering from 12C
Abstract The elastic and inelastic photon scattering from 12 C was investigated in the energy range of the Δ-resonance ( E γ = 200–500 MeV) at a scattering angle of 40°. The experiment was performed with the tagged photon facility at the cw electron accelerator MAMI ( E e − = 855 MeV). By using a large NaI(Tl) detector having an energy resolution of 1.5%, the elastic scattering could be separated from the inelastic process to the first excited state ( E x = 4.44 MeV of 12 C. The differential cross section for the coherent scattering is compared with a simple static ansatz, that uses the known charge form factor, and with a recent Δ-hole calculation.
Emittance Growth by Synchrotron Radiation in a Double-Sided Microtron
Here we present results of calculations of emittance growth caused by quantum fluctuations of synchrotron radiation (QFSR) for a 1.5 GeV double-sided microtron (DSM). We did both semi-analytical estimations, employing known Twiss parameters for the DSM orbits, and a computer simulation of these stochastic effects using the program SYTRACE. This showed that the normalized emittance growth was within reasonable limits, by a factor of about 1.5, thus permitting e.g. the installation of small aperture linacs on the DSM axes.