0000000000585477

AUTHOR

G. Stengel

showing 1 related works from this author

A large-area scintillating fibre detector for relativistic heavy ions

1998

Abstract A scintillating fibre detector for relativistic heavy ions with an active area of 50 × 50 cm 2 has been developed and was tested with various ion beams (1 ≤ Z ≤ 92). At count rates of up to 10 5 particles/s, the position resolution was found to be determined by the fibre width of 1 mm; depending on the nuclear charge of the beam, efficiencies between 89% and 100% and time resolutions between 800 and 200 ps (FWHM) were obtained.

Position sensitive photomultiplierPhysicsNuclear and High Energy PhysicsFull width at half maximumPosition resolutionDetectorScintillating fibreAtomic physicsInstrumentationEffective nuclear chargeBeam (structure)IonNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment