0000000000594136

AUTHOR

Martin Breitenfeldt

Investigation of Space-Charge Phenomena in Gas-Filled Penning Traps

The centering of ions in Penning traps by a quadrupolar radiofrequency excitation in the presence of a buffer gas has been studied in the regime of high charge‐densities. It is found to deviate significantly from the single‐particle situation. In particular, the efficiency of the cooling process is affected as well as the resolving power. The behavior has been studied experimentally at the preparation trap REXTRAP and the high‐precision Penning trap setup ISOLTRAP both located at the on‐line mass separator ISOLDE at CERN. In addition, the phenomenon has been investigated numerically by a custom‐designed simulation.

research product

Time-separated oscillatory fields for high-precision mass measurements on short-lived Al and Ca nuclides

High-precision Penning trap mass measurements on the stable nuclide 27Al as well as on the short-lived radionuclides 26Al and 38,39Ca have been performed by use of radiofrequency excitation with time-separated oscillatory fields, i.e. Ramsey's method, as recently introduced for the excitation of the ion motion in a Penning trap, was applied. A comparison with the conventional method of a single continuous excitation demonstrates its advantage of up to ten times shorter measurements. The new mass values of 26,27Al clarify conflicting data in this specific mass region. In addition, the resulting mass values of the superallowed beta-emitter 38Ca as well as of the groundstate of the beta-emitte…

research product

Approaching theN=82shell closure with mass measurements of Ag and Cd isotopes

Mass measurements of neutron-rich Cd and Ag isotopes were performed with the Penning trap mass spectrometer ISOLTRAP. The masses of ${}^{112,114\ensuremath{-}124}$Ag and ${}^{114,120,122\ensuremath{-}124,126,128}$Cd, determined with relative uncertainties between $2\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}8}$ and $2\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}7}$, resulted in significant corrections and improvements of the mass surface. In particular, the mass of $^{124}\mathrm{Ag}$ was previously unknown. In addition, other masses that had to be inferred from $Q$ values of nuclear decays and reactions have now been measured directly. The analysis includes various mass…

research product

The elliptical Penning trap: Experimental investigations and simulations

Abstract The application of an additional azimuthal quadrupolar electrostatic field to a Penning trap leads to a field configuration referred to as an elliptical Penning trap. The resulting changes of the radial ion motions have been investigated experimentally and by use of simulations. The eigenfrequencies, i.e., the magnetron frequency ω ˜ − and the reduced cyclotron frequency ω ˜ + , are found to be shifted with respect to those of the standard Penning trap ω − , ω + , respectively. As the shift of the magnetron frequency ω ˜ − is larger than that of the reduced cyclotron frequency ω ˜ + their sum ω ˜ + + ω ˜ − is also a function of the ellipticity and no longer equal to the cyclotron f…

research product

High-precision Penning-trap mass measurements of heavy xenon isotopes for nuclear structure studies

With the double Penning-trap mass spectrometer ISOLTRAP at ISOLDE/CERN the masses of the neutron-rich isotopes $^{136\ensuremath{-}146}\mathrm{Xe}$ were measured with a relative uncertainty of the order of ${10}^{\ensuremath{-}8}$ to ${10}^{\ensuremath{-}7}$. In particular, the masses of $^{144\ensuremath{-}146}\mathrm{Xe}$ were measured for the first time. These new mass values allow one to extend calculations of the mass surface in this region. Proton-Neutron interaction strength, obtained from double differences of binding energies, relate to subtle structural effects, such as the onset of octupole correlations, the growth of collectivity, and its relation to the underlying shell model l…

research product

Damping effects in Penning trap mass spectrometry

Abstract Collisions of ions with residual gas atoms in a Penning trap can have a strong influence on the trajectories of the ions, depending on the atom species and the gas pressure. We report on investigations of damping effects in time-of-flight ion-cyclotron resonance mass spectrometry with the Penning trap mass spectrometers ISOLTRAP at ISOLDE/CERN (Geneva, Switzerland) and SHIPTRAP at GSI (Darmstadt, Germany). The work focuses on the interconversion of the magnetron and cyclotron motional modes, in particular the modification of the resonance profiles for quadrupolar excitation due to the damping effect of the residual gas. Extensive experiments have been performed with standard and Ra…

research product