Leber-CT mit portal-venöser Kontrastmittelgabe
Contrast administration through the superior mesenteric or splenic arteries provided additional information in 22 out of 31 patients, when compared with intravenous contrast bolus for CT of the liver. In 11 patients, the demonstration of a tumour lead to a change in treatment. False positive findings occurred in four of the 31 patients. In 2 patients intrahepatic lesions were overlooked, but were found during angiography carried out at the same examination. The diagnosis of intrahepatic space-occupying lesions is discussed as well as the CT appearances of portal-venous liver perfusion.
Zur Diagnostik atherosklerotischer Läsionen der extrakraniellen Arteria carotis mit Duplexsonographie und IA-DSA
Fifty patients were studied prospectively. The extracranial portions of the carotid arteries were examined by duplex sonography and IA-DSA in order to demonstrate haemodynamically significant stenoses or plaques which might give rise to emboli and the findings compared with the pathologic specimens. The results indicate high sensitivity (up to 90%) for more than 75% detection of stenoses. On the other hand ulceration was diagnosed sonographically with an accuracy of 66% and plaque hemorrhage with an accuracy of 56%.