0000000000599483

AUTHOR

Alexej Grudiev

High Gradient Performance of an S-Band Backward Traveling Wave Accelerating Structure for Medical Hadron Therapy Accelerators

The high-gradient performance of an accelerating structure prototype for a medical proton linac is presented. The structure was designed and built using technology developed by the CLIC collaboration and the target application is the TULIP (Turning Linac for Proton therapy) proposal developed by the TERA foundation. The special feature of this design is to produce gradient of more than 50 MV /m in low-β accelerating structures (v/c=0.38). The structure was tested in an S-band test stand at CERN. During the tests, the structure reached over above 60 MV/m at 1.2 μs pulse length and breakdown rate of about 5x10⁻⁶ bpp. The results presented include ultimate performance, long term behaviour and …

research product

CERN’s Linac4 cesiated surface H− source

Linac4 cesiated surface H− sources are routinely operated for the commissioning of the CERN’s Linac4 and on an ion source test stand. Stable current of 40-50 mA are achieved but the transmission through the LEBT of 80% was below expectations and triggered additional beam simulation and characterization. The H− beam profile is not Gaussian and emittance measurements are larger than simulation. The status of ongoing development work is described; 36 mA H− and 20 mA D− beams were produced with a 5.5 mm aperture cesiated surface ion source. The emittances measured at the test stand are presented. During a preliminary test, the Linac4 proton source delivered a total beam intensity of 70 mA (p, H…

research product