Alexandre Romaine

Rôle des espèces sulfures dans la corrosion des aciers non alliés : hétérogénéités de la couche de produits de corrosion et couplages galvaniques

The present study relates to the problem of the long-term interim storage of nuclear wastes. In France, it is envisaged that high-level radioactive wastes will be confined in a glass matrix, stored in a stainless steel canister, itself placed in a carbon steel overpack. The wastes will then be stored at a depth of ~450 m in a deep geological disposal, drilled in a very stiff (indurated) clay (argillite) formation. A temperature as high as 90°C is expected at the steel surface because of the intense radioactivity. Anodic polarization at applied current density was used to synthetize corrosion product layers likely to be formed in storage conditions. The S235 steel electrodes were covered by …

research product

Influence of post-treatment time of trivalent chromium protection coating on aluminium alloy 2024-T3 on improved corrosion resistance

Abstract Low corrosion protection performances of Trivalent Chromium Process (TCP) coatings with reference to Chromium Conversion Coatings (CCC) deposited on aluminium alloys can be overcome by application of post-treatment processes. This work shows the effect of post-treatment bath (containing hydrogen peroxide and lanthanum salt) on the chemical composition, structure and the corrosion performances of TCP coating deposited on AA 2024-T3 aluminium alloy. Different times of post-treatment bath were applied on the TCP coating and the samples were analyzed by Time-of-Flight Secondary Ion Mass Spectrometry (ToF-SIMS), X-ray Photoelectron Spectroscopy (XPS) and Glow Discharge-Optical Emission …

research product