0000000000602756
AUTHOR
Daniela Leitner
Studies of electron heating on a 6.4 GHz ECR ion source through measurement of diamagnetic current and plasma bremsstrahlung
Diamagnetic current and low energy (2–70 keV) x-ray bremsstrahlung measurements taken on a 6.4 GHz electron cyclotron resonance ion source (ECRIS) are presented as a function of microwave power, neutral gas pressure and magnetic field configuration. X-ray flux from confined electrons and plasma energy density depend logarithmically on microwave power. This result differs from previous studies performed on ECRISs that operate at higher microwave frequencies, in which the x-ray power increases in an essentially linear fashion with the microwave power. X-ray power and plasma energy density both saturate as the neutral pressure is increased beyond a certain value. The gradient of the magnetic f…
Plasma response to amplitude modulation of the microwave power on a 14 GHz electron cyclotron resonance ion source
This paper reports the effects of sinusoidal microwave power Amplitude Modulation (AM) on the performance of Electron Cyclotron Resonance (ECR) ion sources. The study was conducted on the 14 GHz ECR ion source ECR2 at the University of Jyväskylä. The klystron output was intentionally altered by a variable frequency sinusoidal amplitude modulation. The average microwave power 350 W was modulated between 530 W and 180 W from 0.011-25 kHz. The integrated x-ray energy, the mass analyzed beam current and the forward and reflected microwave power were measured. The energy integrated x-ray signal responded strongly with low frequency modulation and was no longer observable at approximately 2.2 kHz…
The effect of rf pulse pattern on bremsstrahlung and ion current time evolution of an ECRIS.
Time-resolved helium ion production and bremsstrahlung emission from JYFL 14 GHz ECRIS is presented with different radio frequency pulse lengths. rf on times are varied from 5 to 50 ms and rf off times from 10 to 1000 ms between different measurement sets. It is observed that the plasma breakdown occurs a few milliseconds after launching the rf power into the plasma chamber, and in the beginning of the rf pulses a preglow transient is seen. During this transient the ion beam currents are increased by several factors compared to a steady state situation. By adjusting the rf pulse separation the maximum ion beam currents can be maintained during the so-called preglow regime while the amount o…
Studies of plasma breakdown and electron heating on a 14 GHz ECR ion source through measurement of plasma bremsstrahlung
Temporal evolution of plasma bremsstrahlung emitted by a 14?GHz electron cyclotron resonance ion source (ECRIS) operated in pulsed mode is presented in the energy range 1.5?400?keV with 100??s resolution. Such a high temporal resolution together with this energy range has never been measured before with an ECRIS. Data are presented as a function of microwave power, neutral gas pressure, magnetic field configuration and seed electron density. The saturation time of the bremsstrahlung count rate is almost independent of the photon energy up to 100?keV and exhibits similar characteristics with the neutral gas balance. The average photon energy during the plasma breakdown is significantly highe…