Right ventricular lead placement and ventricular dyssynchrony in a pacemaker population: An acute analysis from the evaluation of apical and non-apical position (right pace) study.
Magnitude of QRS duration reduction after biventricular pacing identifies responders to cardiac resynchronization therapy
Background Several studies have investigated the association between native QRS duration (QRSd) or QRS narrowing and response to biventricular pacing. However, their results have been conflicting. The aim of our study was to determine the association between the relative change in QRS narrowing index (QI) and clinical outcome and prognosis in patients who undergo cardiac resynchronization therapy (CRT) implantation. Methods and results We included 311 patients in whom a CRT device was implanted in accordance with current guidelines for CRT. On implantation, the native QRS, the QRSd and the QI during CRT were measured. After 6 months, 220 (71%) patients showed a 10% reduction in LVESV. The m…
Mortality after cardioverter-defibrillator replacement: Results of the DECODE survival score index
Background Device replacement is the ideal time to reassess health care goals regarding continuing implantable cardioverter-defibrillator (ICD) therapy. Only few data are available on the decision making at this time. Objectives The goals of this study were to identify factors associated with poor prognosis at the time of ICD replacement and to develop a prognostic index able to stratify those patients at risk of dying early. Methods DEtect long-term COmplications after implantable cardioverter-DEfibrillator replacement (DECODE) was a prospective, single-arm, multicenter cohort study aimed at estimating long-term complications in a large population of patients who underwent ICD/cardiac resy…
Is there a right place to pace the right ventricle? Evaluation of apical and septal positions in a pacemaker population: Study protocol for a prospective intervention-control trial
Abstract Introduction The main objective of research in pacemaker therapy has been to provide the best physiologic way to pace the heart. Despite the good results provided by right ventricular pacing minimization and by biventricular pacing in specific subsets of heart failure patients, these options present many limitations for standard pacemaker recipients. In these patients, pacing the right ventricle at alternative sites could result in a lower degree of left intraventricular dyssynchrony. Despite the lack of strong evidence and the difficulty in placing and accurately classifying the final lead position, pacing at alternative right ventricular sites seems to have become a standard proc…
Detect Long-term Complications After ICD Replacement (DECODE): Rationale and Study Design of a Multicenter Italian Registry
The replacement of implantable cardioverter-defibrillators (ICDs) may give rise to considerable clinical consequences, the importance of which is underrated by the medical community. Replacement-related adverse events are difficult to identify and require monitoring of both short-term complications and long-term patient outcome. The aim of this study is to perform a structured evaluation of both short- and long-term adverse events and a cost analysis of consecutive ICD replacement procedures. Detect Long-term Complications After ICD Replacement (DECODE) is a prospective, single-arm, multicenter cohort study designed to estimate long-term complication rates (at 12 months and 5 years) in pati…