0000000000626769

AUTHOR

R Ienzi

showing 4 related works from this author

Can 3D Digital Breast Tomosynthesis (DBT) improve breast malignant pathology detection? A case-to-case imaging comparison between 3D DBT and 2D Mammo…

2014

Learning objectives Background Findings and procedure details Conclusion Personal information References

Breast Mammography Digital radiography Screening Computer Applications-3D eLearning Cancer Education and traininggenetic structuresComputer Applications-3DeducationEducation and trainingDigital radiographyScreeningeLearningBreastMammographyCancer
researchProduct

High-rate x-ray spectroscopy in mammography with a CdTe detector: A digital pulse processing approach

2010

Purpose:Direct measurement of mammographic x-ray spectra under clinical conditions is a difficult task due to the high fluence rate of the x-ray beams as well as the limits in the development of high resolution detection systems in a high counting rate environment. In this work we present a detection system, based on a CdTe detector and an innovative digital pulse processing (DPP) system, for high-rate x-ray spectroscopy in mammography. Methods: The DPP system performs a digital pile-up inspection and a digital pulse height analysis of the detector signals, digitized through a 14-bit, 100 MHz digitizer, for x-ray spectroscopy even at high photon counting rates. We investigated on the respon…

x-ray spectroscopy CdTe detectors high photon counting rate digital pulse processing mammography
researchProduct

Fast Fourier Transform Filtering for Bilateral Mammography Comparison

2010

Bilateral Asymmetry is one of the breast abnormalities that may indicate a cancer in early stage. The computer methods for the bilateral subtraction developed up to now show the problem of large false positives number because the alignment defects. On the other hand the computer methods using FFT approach suffer of a low S/N ratio to distinguish massive lesions from background. In this paper a method (FFT-RF-BMC) is presented to enhanche the bilateral asymmetry using a FFT to detect massive lesions through a Recursive Filtering.

Settore ING-INF/05 - Sistemi Di Elaborazione Delle InformazioniSettore FIS/01 - Fisica SperimentaleCAD mammography FFT Bilateral Mammography Comparison Computer ApplicationsSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)
researchProduct

Aspetti mammografici, ecografici e di RM del carcinoma lobulare

2008

carcinoma lobularemammelladiagnosi
researchProduct