0000000000627722
AUTHOR
B.g. Semporé
Analysis and fractionation of natural source diacylglycerols as urethane derivatives by reversed-phase high-performance liquid chromatography
Abstract Reversed-phase high-performance liquid chromatography on a thermostatted octadecylsilyl column was used to separate and fractionate mixtures of diacylglycerols after derivatization with 3,5-dinitrophenyl isocyanate (urethane derivatives). In addition to the separation of commercial diacylglycerol species, the separation of diacylglycerols obtained from peanut oil and cottonseed oil triacylglycerols by chemical hydrolysis is reported. Acetonitrile-acetone mixtures were used for elution of the diacylglycerol urethane derivatives. Unsaturated and saturated derivatives were detected by their refractive indices. They were then collected and their fatty acids analysed as methyl esters by…
Enantiomer separation by chiral-phase liquid chromatography of urethane derivatives of natural diacylglycerols previously fractionated by reversed-phase liquid chromatography
Abstract Enantiomers of diacylglycerols such as 3,5-dinitrophenyl isocyanate (urethane) derivatives previously fractionated by reversed-phase high-performance liquid chromatography (HPLC) were separated by HPLC on a chiral phase column [N-( R )-1-(α-naphthyl)ethylamino-carbonyl-( S )-valine chemically bound to γ-aminopropylsilanized silica]. In addition to the separation of commercial monoacid-diacylglycerol isomers, separation of diacid-diacylglycerol isomers obtained from peanut oil and cottonseed oil triacylglycerols by chemical hydrolysis is reported. Hexane-ethylene dichloride-ethanol mixtures were used for elution of the diacylglycerol derivative isomers, which were detected by their …
Separation of monoacylglycerols by reversed-phase high-performance liquid chromatography
Abstract Reversed-phase high-performance liquid chromatography on a thermostated octadecylsilyl column was used to separate complex mixtures of monoacyglycerols formed by chemical deacylation of natural triacyclycerols. Acetonitrile-water mixtures were used for elution of the underivatized monoacylglycerols and a different refractometer was used for their detection. The order of elution of monoacylglycerols in complex mixtures varies as a function of the chain length, unsaturation, positional isomerism, analysis temperature and eluent water concentration. The peak areas were representative of the amounts of monoacylglycerols detected. The method can be applied to compositional analysis and …