Repeatability of the resonance frequency analysis values in implants with a new technology

2019

Background Assess the reliability (by means of reproducibility and repeatability) of the PenguinRFA system, analyse the ISQ values of different implant types and correlate the ISQ with the insertion torque during the placement of the implant. Material and Methods 120 rough surface implants were placed in bovine bone (type II and III). The implants were divided into groups, according to its design. Once the implants were in place, the exact insertion torque was registered. Then, primary stability was measured by means of the resonance frequency analysis with the PenguinRFA and the Osstell ISQ devices. In each implant two transducers of each device were used. Three measurements were obtained …

Materials scienceIntraclass correlationVibrationDental Prosthesis Retention03 medical and health sciences0302 clinical medicineAnimalsGeneral DentistryDental ImplantsReproducibilityResearchDental Implantation EndosseousResonance Frequency AnalysisReproducibility of Results030206 dentistryRepeatability:CIENCIAS MÉDICAS [UNESCO]Implant stability quotientResonance frequency analysisDental Prosthesis DesignTorqueOtorhinolaryngologyRough surfaceUNESCO::CIENCIAS MÉDICASImplant typesCattleSurgeryImplantOral SurgeryBiomedical engineeringMedicina Oral Patología Oral y Cirugia Bucal
researchProduct

Assessment of periapical status : a comparative study using film-based periapical radiographs and digital panoramic images

2009

Aim: To compare the use of film-based periapical radiographs and digital panoramic images displayed on monitor and glossy paper in the assessment of the periapical status of the teeth. Methodology: A total of 86 subjects were examined. All participants underwent a full-mouth radiographic survey (14 periapical radiographs) and a digital panoramic radiography. The periapical status of all appraised teeth was assessed. Results: Periapical radiographs allowed the assessment of the periapical status of a significantly higher percentage of teeth (87.4%) Digital radiography had a significantly reduced potential to allow assessment of the periapical status (p<0.01). Only 58.0% and 34.3% of teeth co…

AdultMaleRadiographyDentistrystomatognathic systemRadiography PanoramicMedicineHumansGeneral DentistryDigital radiographyAgedOrthodonticsPeriodontitisbusiness.industryPeriapical radiographyPeriapical TissueRadiography Dental DigitalMiddle Agedmedicine.disease:CIENCIAS MÉDICAS [UNESCO]stomatognathic diseasesOtorhinolaryngologyUNESCO::CIENCIAS MÉDICASSurgeryFemalebusiness
researchProduct

Assessment of Osstell ISQ's reliability for implant stability measurement: a cross-sectional clinical study

2013

Resonance frequency analysis (RFA) allows assess implant stability by measuring implant oscillation frequency on the bone. RFA is an objective and non-invasive method for implant stability measurement, although scarce evidence has been provided so far on its reliability. Objectives: Assess the Osstell ISQ system's reliability (i.e., its measurement reproducibility and repeatability) by means of the intraclass correlation coefficient (ICC) as statistical method. Study Desing: Implants stability registers were completed by means of Osstell ISQ on 85 implants on 23 patients. Six measurements were completed on each implant by means of two different SmartPegs (types I and II); that is, three con…

Intraclass correlationDentistryOdontologíaVibrationStability (probability)Clinical studyHumansDental Restoration FailureGeneral DentistryReliability (statistics)MathematicsDental ImplantsOrthodonticsReproducibilitybusiness.industryReproducibility of ResultsRepeatability:CIENCIAS MÉDICAS [UNESCO]Ciencias de la saludBiomechanical PhenomenaResonance frequency analysisCross-Sectional StudiesOtorhinolaryngologyUNESCO::CIENCIAS MÉDICASResearch-ArticleSurgeryImplantbusinessImplantology
researchProduct

Resonance frequency analysis-reliability in third generation instruments : Osstell mentor ®

2012

Few studies assess repeatability and reproducibility in registers of resonance frequency analysis (a value of dental implant stability). Objective: Few studies assess repeatability and reproducibility in resonance frequency analyses (implant stability evaluation). This study is aimed at assessing reliability (repeatabilty and reproducibility) in the Osstell Mentor® system using the intraclass correlation coefficient (ICC) as the statistical method. Study Design: ISQ measurements of RFA were carried out by means of the Osstell Mentor ® instrument in 58 implants in 19 patients. Six measurements were performed on each implant by means of two different Smart-Pegs (I and II). Three consecutive m…

medicine.medical_specialtyIntraclass correlationmedicine.medical_treatmentmedicineHumansPeriodontologyDental implantGeneral DentistryReliability (statistics)Dental ImplantsReproducibilitybusiness.industryReproducibility of ResultsRepeatability:CIENCIAS MÉDICAS [UNESCO]Confidence intervalSurgeryDental ImplantationResonance frequency analysisOtorhinolaryngologyUNESCO::CIENCIAS MÉDICASResearch-ArticleSurgeryImplantbusinessBiomedical engineering